Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2029014
Status:
Active
Facility Name:
Chicago Beverage System, Inc.
Address:
441 N. Kilbourn Ave. Chicago, IL 60624
County:
Cook
Property Parcel:
13-15-130-011-0000
Facility Type:
Commercial / Retail
Owner Type:
Private
Green Tag Decal:
Z003920
Green Tag Issue Date:
4/5/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
Chicago Beverage System Inc
Owner Address:
441 N Kilbourn Ave Chicago, IL 60624
Owner Status:
Current Owner
Purchase Date:
10/31/1986
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
8/16/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
10/17/2022
12/31/2024
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0018476
Chicago Beverage System Inc
Current Owner
10/31/1986
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2024-0682
9/9/2024
Removal Log
00978-2024REM
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/9/2024
OSFM
First Notify Date:
12/27/1991
Abandoned Material:
Current Age:
41
Abandoned Date:
Install Date:
12/1/1982
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
4/12/2022
4/12/2027
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Gilbarco EMC
10/6/2023
10/6/2024
Overfill Prev Device
Overfill Alarm
10/6/2023
10/6/2026
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
3/21/2024
3/21/2027
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping Ameron
Precision Test (Piping)
Pass
4/14/2022
Tank
Steel Single Wall
Precision Test (Tank)
Pass
4/14/2022
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/9/2024
OSFM
First Notify Date:
12/27/1991
Abandoned Material:
Current Age:
41
Abandoned Date:
Install Date:
12/1/1982
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
4/12/2022
4/12/2027
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Gilbarco EMC
10/6/2023
10/6/2024
Overfill Prev Device
Overfill Alarm
10/6/2023
10/6/2026
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
3/21/2024
3/21/2027
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping Ameron
Precision Test (Piping)
Pass
4/14/2022
Tank
Steel Single Wall
Precision Test (Tank)
Pass
3/31/2023
Tank Number 3
Capacity:
10000
Petroleum Use:
None
Product:
Low Sulfur Diesel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/27/2024
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
9/29/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
3/23/2024
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
3/21/2024
3/21/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
3/21/2024
3/21/2025
Overfill Prev Device
Overfill Alarm
3/21/2024
3/21/2027
Overfill Prev Device
Overfill Drop Tube Valve
3/22/2024
3/22/2027
Piping
Fiberglass Double Wall Ameron Dualoy 3000/LCX
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/21/2024
3/21/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
3/21/2024
3/21/2025
Spill Contain Device
Double Wall Spill Bucket
3/21/2024
3/21/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall Ameron Dualoy 3000/LCX
Precision Test (Piping)
Pass
3/21/2024
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
3/22/2024
Tank Number 4
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Non Ethanol
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/27/2024
Abandoned Material:
Current Age:
1
Abandoned Date:
Install Date:
9/29/2023
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
3/23/2024
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
3/21/2024
3/21/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
3/21/2024
3/21/2025
Overfill Prev Device
Overfill Alarm
3/21/2024
3/21/2027
Overfill Prev Device
Overfill Drop Tube Valve
3/22/2024
3/22/2027
Piping
Fiberglass Double Wall Ameron Dualoy 3000/LCX
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/21/2024
3/21/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
3/21/2024
3/21/2025
Spill Contain Device
Double Wall Spill Bucket
3/21/2024
3/21/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall Ameron Dualoy 3000/LCX
Precision Test (Piping)
Pass
3/21/2024
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
3/22/2024
Dispenser Information
Name\ID 1
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/21/2024
3/21/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
3/21/2024
3/21/2025
Name\ID 4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/21/2024
3/21/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
3/21/2024
3/21/2025
Name\ID 5
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/21/2024
3/21/2027
Leak Detect - Piping
Sump Sensor with positive shutdown
3/21/2024
3/21/2025
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
2029014
Chicago Beverage System, Inc.
Chicago
03/26/2024
Letter
Form