Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2027637
Status: Closed
Facility Name: Ridge Country Club
Address: 10522 S California
Chicago, IL 60655
County: Cook
Property Parcel:
Facility Type: Golf Course
Owner Type: Private
Green Tag Decal: X002100
Green Tag Issue Date: 6/27/2022
Green Tag Expiration Date: 3/23/2023

Owner Details

Owner Name: Ridge Country Club
Owner Address: 10522 S California
Chicago, IL 60655
Owner Status: Current Owner
Purchase Date: 10/1/1991
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/21/2023

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 6/27/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0017516 Ridge Country Club Current Owner 10/1/1991

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2023-0217 3/20/2023 Removal Log 00223-2023REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20230217 Eligible 4/7/2023 4/12/2023 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/30/1991
OSFM First Notify Date: 7/16/1991 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1991 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/30/1991
OSFM First Notify Date: 7/16/1991 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/1/1991 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/20/2023
OSFM First Notify Date: 1/11/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 10/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 10/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 12/8/2022 12/8/2025
Corrosion Prot - Piping Composite Chase N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 6/23/2022 6/23/2023
Overfill Prev Device Overfill Drop Tube Valve 7/27/2022 7/27/2025
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor 8/26/2019 8/26/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/27/2022 7/27/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall Precision Test (Tank) Pass 4/25/2022



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/20/2023
OSFM First Notify Date: 1/11/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 10/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 10/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Composite Chase N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 6/23/2022 6/23/2023
Overfill Prev Device Overfill Drop Tube Valve 7/27/2022 7/27/2025
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor 8/26/2019 8/26/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/27/2022 7/27/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall Precision Test (Tank) Pass 4/25/2022

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found