Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041353 |
Brake Time IL Properties, LLC |
Current Owner |
11/6/2024 |
| U0041353 |
Brake Time IL Properties, LLC |
Former Owner |
11/5/2024 |
| U0039389 |
Minit Mart, LLC |
Former Owner |
12/5/2018 |
| U0026726 |
TA Operating, LLC |
Former Owner |
8/13/2015 |
| U0010459 |
MKM Oil, Inc. |
Former Owner |
1/3/1990 |
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00154-2026CAT |
Cathodic Protection |
Approved / Issued |
2/11/2026 |
2/11/2026 |
8/11/2026 |
Documents |
Notice of Violations (Current)
NOV Number:
E0020260072
(Pending)
Issue Date:
1/12/2026
Expiration Date:
3/13/2026
View NOV Form
| Tanks |
Violations |
| 1, 3 |
Flex connector sacrificial anode system not tested (required every 3 years) - Test anodes and replace as needed - 175.510 f)2)A)i) Sacrificial anodes shall be tested every 3 years as long as
testing results are -850 millivolts or a higher negative
number. In the event testing results do not meet the -850
millivolt requirement, the anodes shall be replaced. This
requirement applies to all sacrificial anodes, including
wristband and spike anodes. |
| 1, 2, 3 |
Tank sacrificial anode system not tested (Required every 3 years). - 175.510 f)2)A)i) Sacrificial anodes shall be tested every 3 years as long as
testing results are -850 millivolts or a higher negative
number. In the event testing results do not meet the -850
millivolt requirement, the anodes shall be replaced. This
requirement applies to all sacrificial anodes, including
wristband and spike anodes. |
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1990 |
|
Abandoned Material: |
|
| Current Age: |
36 |
|
Abandoned Date: |
|
| Install Date: |
3/6/1990 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/6/1990 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
2/23/2026 |
2/23/2029 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
2/23/2026 |
2/23/2029 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/16/2025 |
9/16/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Red Jacket Pro Max with CSLD |
9/16/2025 |
9/16/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
12/6/2024 |
12/6/2027 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
12/6/2024 |
12/6/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
9/30/2024
|
Tank Number 2
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1990 |
|
Abandoned Material: |
|
| Current Age: |
36 |
|
Abandoned Date: |
|
| Install Date: |
3/6/1990 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/6/1990 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/23/2026 |
2/23/2029 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/16/2025 |
9/16/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Red Jacket Pro Max with CSLD |
9/16/2025 |
9/16/2026 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
12/6/2024 |
12/6/2027 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
12/6/2024 |
12/6/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
9/30/2024
|
Tank Number 3
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/18/1990 |
|
Abandoned Material: |
|
| Current Age: |
36 |
|
Abandoned Date: |
|
| Install Date: |
3/6/1990 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/6/1990 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
2/23/2026 |
2/23/2029 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/23/2026 |
2/23/2029 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/16/2025 |
9/16/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Red Jacket Pro Max with CSLD |
9/16/2025 |
9/16/2026 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
12/27/2024 |
12/27/2027 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
12/6/2024 |
12/6/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
9/30/2024
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
Not applicable
|
Not applicable
|
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable
|
Not applicable
|
Name\ID 7/8
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
Not applicable
|
Not applicable
|
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable
|
Not applicable
|
Name\ID 9/10
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found