Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2025361
Status: Active
Facility Name: North West Mosquito Abatement District
Address: 1600 Bartlett Road
Hoffman Estates, IL 60195
County: Cook
Property Parcel:
Facility Type: County
Owner Type: County
Green Tag Decal: Y003807
Green Tag Issue Date: 9/22/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: North West Mosquito Abatement District
Owner Address: 147 West Hintz Road
Wheeling, IL 60090
Owner Status: Current Owner
Purchase Date: 7/31/1967
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 5/19/2023 12/31/2025
Fleet 5/19/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0011185 North West Mosquito Abatement District Current Owner 7/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
91-3511 12/5/1991 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
91-3511 Eligible 3/15/1996 3/15/1996 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/5/1991
OSFM First Notify Date: 11/20/1989 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 7/31/1967 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/1967

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/3/1993 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 4/1/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/4/2024 6/4/2025
Overfill Prev Device Overfill Drop Tube Valve 6/4/2024 6/4/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank Composite Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID MIDGRADE

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found