Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2025220
Status: Active
Facility Name: North West Mosquito Abatement District
Address: 147 West Hintz Road Wheeling, IL 60090
County: Cook
Property Parcel:
Facility Type: Utility
Owner Type: Other Local
Green Tag Decal: AA03956
Green Tag Issue Date: 8/5/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Fleet

Owner Details

Owner Name: North West Mosquito Abatement District
Owner Address: 147 West Hintz Road Wheeling, IL 60090
Owner Status: Current Owner
Purchase Date: 8/1/1989
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0011185 North West Mosquito Abatement District Current Owner 8/1/1989

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2025-0912 12/3/2025 Removal Log 01599-2025REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/20/1989 Abandoned Material:
Current Age: 59 Abandoned Date:
Install Date: 11/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 9/20/2022 9/20/2027
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 5/20/2026 5/20/2027
Overfill Prev Device Overfill Alarm 6/3/2025 6/3/2028
Piping Fiberglass Double Wall Ameron Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 6/4/2024 6/4/2027
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 8/23/2022



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 12/3/2025
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID REG

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms