Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2025054
Status: Active
Facility Name: 127 Food & Fuel
Address: 1336 W. 127th St.
Calumet Park, IL 60827
County: Cook
Property Parcel: 25-29-325-067-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00289
Green Tag Issue Date: 4/15/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Standard Bank & Trust Company Trust #18465
Owner Address: 7800 W. 95th Street
Hickory Hills, IL 60456
Owner Status: Current Owner
Purchase Date: 9/9/2004
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/6/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/15/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041185 Standard Bank & Trust Company Trust #18465 Current Owner 9/9/2004
U0039129 Calumet Gulf, Inc. Former Owner 4/12/2018
U0030523 Abdelkader, Soufian Former Owner 4/5/2006
U0033668 Buddy's Citgo, Inc. Former Owner 9/23/2004
U0023235 Stan Zervos/NTZ Corp. Former Owner 5/1/1987
U0005946 Godbout Joseph Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-0814 9/3/2014 Abandonment Log 00661-2014ABN
2023-0391 5/16/2023 Removal Log 00438-2023REM
2023-0391 5/17/2023 Removal Log 00438-2023REM
2023-0391 5/18/2023 Removal Log 00438-2023REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
00-0332 Eligible 3/24/2000 3/30/2000 $15,000
14-0814 Eligible 9/9/2014 10/29/2014 $5,000
20140814 Eligible 6/25/2018 6/27/2018 $5,000 Letter
20230391 Eligible 5/22/2024 5/28/2024 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/18/2023
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 47 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/1/2018 2/1/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/25/2022 1/25/2023
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD 1/25/2022 1/25/2023
Overfill Prev Device Overfill Drop Tube Valve 1/25/2022 1/25/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/25/2022 1/25/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 1/25/2022



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/17/2023
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 47 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/1/2018 2/1/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/25/2022 1/25/2023
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD 1/25/2022 1/25/2023
Overfill Prev Device Overfill Drop Tube Valve 1/25/2022 1/25/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/25/2022 1/25/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 1/25/2022
Tank Steel Single Wall Precision Test (Tank) Pass 8/3/2021



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/17/2023
OSFM First Notify Date: 3/26/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 47 Abandoned Date: 9/3/2014
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 7/23/2010 7/23/2015
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/23/2010 7/23/2011
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/16/2023
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 47 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: 1/24/2018 Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 1/24/2018 1/24/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/28/2016 4/28/2017
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 550 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/28/2000
OSFM First Notify Date: 7/1/1992 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 1/1/1975 Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 550 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 3/28/2000
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 1/1/1975 Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/6/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/29/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max 9/18/2024 9/18/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/6/2023 9/6/2026
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/18/2024 9/18/2025
Spill Contain Device Double Wall Spill Bucket 9/6/2023 9/6/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 9/18/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/28/2023



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/6/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/29/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max 9/18/2024 9/18/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/6/2023 9/6/2026
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/18/2024 9/18/2025
Spill Contain Device Double Wall Spill Bucket 9/6/2023 9/6/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 9/18/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/28/2023



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/6/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 6/29/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/18/2024 9/18/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max 9/18/2024 9/18/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/18/2024 9/18/2025
Overfill Prev Device Overfill Drop Tube Valve 9/6/2023 9/6/2026
Piping Flexible Double Wall NUPI Smartflex N/A N/A
Piping Single Wall STP/Tanktop Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/18/2024 9/18/2025
Spill Contain Device Double Wall Spill Bucket 9/6/2023 9/6/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall NUPI Smartflex Precision Test (Piping) Pass 9/18/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/28/2023

Dispenser Information



Name\ID 1/2

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/18/2024 9/18/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/18/2024 9/18/2025



Name\ID 3/4

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 5/6

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/18/2024 9/18/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/18/2024 9/18/2025



Name\ID 7/8

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Dispenser Single Wall UDC Sump 9/6/2023 9/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/6/2023 9/6/2024

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2025054 127 Food & Fuel Calumet Park 09/07/2023 Letter Form