Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2024612
Status: Active
Facility Name: Casey's #6524
Address: 1400 N. Arlington Heights Road Itasca, IL 60143
County: Du Page
Property Parcel: 03-05-200-039
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: BB01391
Green Tag Issue Date: 5/4/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Self Service

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave. P.O. Box 3004 Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 5/14/2021
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 5/14/2021
U0036012 Buchanan Energy (S), LLC Former Owner 12/9/2010
U0010471 ExxonMobil Oil Corporation Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00531-2026UPG Upgrade Cancelled by Contractor 5/11/2026 5/11/2026 11/12/2026 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
15-0568 6/25/2015 Removal Log 00476-2015REM
15-0568 6/25/2015 Removal Log 00476-2015REM
15-0568 6/30/2015 Removal Log 00476-2015REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
15-0568 Eligible 7/8/2015 7/28/2015 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/25/2015
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 12/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1986

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/12/2014 2/12/2015
Leak Detect - Piping Sump Sensor 2/12/2014 2/12/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/25/2015
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 12/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1986

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/12/2014 2/12/2015
Leak Detect - Piping Sump Sensor 2/12/2014 2/12/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/25/2015
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 12/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1986

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/12/2014 2/12/2015
Leak Detect - Piping Sump Sensor 2/12/2014 2/12/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1990
OSFM First Notify Date: 5/21/1990 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1989 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/30/2015
OSFM First Notify Date: 10/22/1991 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 8/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/15/1990

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Gravity Feed Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Less than 25 gallon fills Not applicable Not applicable
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 6

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/4/2017 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 9/4/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/18/2026 5/18/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/18/2026 5/18/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/18/2026 5/18/2027
Overfill Prev Device Overfill Drop Tube Valve 5/1/2024 5/1/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/19/2025 6/19/2028
Spill Contain Device Single Wall Spill Bucket 5/1/2024 5/1/2027
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/9/2022
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/9/2022



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/4/2017 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 9/4/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/18/2026 5/18/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/18/2026 5/18/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/18/2026 5/18/2027
Overfill Prev Device Overfill Drop Tube Valve 5/1/2024 5/1/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/19/2025 6/19/2028
Spill Contain Device Single Wall Spill Bucket 5/1/2024 5/1/2027
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/9/2022
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/9/2022



Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/4/2017 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 9/4/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/18/2026 5/18/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 5/18/2026 5/18/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/18/2026 5/18/2027
Overfill Prev Device Overfill Drop Tube Valve 5/1/2024 5/1/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/19/2025 6/19/2028
Spill Contain Device Single Wall Spill Bucket 5/1/2024 5/1/2027
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 2/9/2022
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 2/9/2022

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/19/2025 6/19/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/18/2026 5/18/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found