Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2023551
Status: Active
Facility Name: Verizon
Address: 10300 S. Oxford Ave.
Chicago Ridge, IL 60415
County: Cook
Property Parcel:
Facility Type: Utility
Owner Type: Private
Green Tag Decal: Y004571
Green Tag Issue Date: 9/28/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: MCI d/b/a Verizon Business
Owner Address: 2 Hampshire St.
Lawrence, MA 01840
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/23/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0022133 MCI d/b/a Verizon Business Current Owner
U0009999 MCI / Verizon Business d/b/a MCI Former Owner 12/1/1993

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 2

Capacity: 600 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/7/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 12/1/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Annual Prec Line Testing Suction 1/6/2017 1/6/2018
Leak Detect - Tank Automatic Tank Gauging Pneumercator TMS 2000 12/18/2024 12/18/2025
Overfill Prev Device Overfill Alarm 12/13/2022 12/13/2025
Overfill Prev Device Overfill Drop Tube Valve 12/13/2022 12/13/2025
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/14/2022 12/14/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Annual Prec Line Testing Suction Functional Pass 12/18/2024
Piping Fiberglass Double Wall Precision Test (Piping) Pass 12/13/2022
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 12/18/2024



Tank Number 3

Capacity: 550 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/29/1993
OSFM First Notify Date: 7/10/1986 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/29/1993 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found