Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2023371
Status: Active
Facility Name: West Chicago Citgo
Address: 250 S. Neltnor Blvd. West Chicago, IL 60185
County: Du Page
Property Parcel: 04-10-119-063
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003363
Green Tag Issue Date: 11/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Amirali Sayani
Owner Address: 1100 Chetwood Drive Carol Stream, IL 60188
Owner Status: Current Owner
Purchase Date: 11/1/1984
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/5/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/12/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031445 Sayani, Amirali Current Owner 11/1/1984
U0013462 Shah, Nadir Former Owner 6/1/2007

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01556-2025UPG Upgrade Approved / Issued 11/18/2025 11/19/2025 5/19/2026 Documents

Notice of Violatlions (Current)

NOV Number: E0020250314 (Referred to Legal)    Issue Date: 2/5/2025    Expiration Date: 4/6/2025    View NOV Form

Tanks Violations
1, 2 Miscellaneous - ATG is in alarm. T1 Gross Test Fail, T2 Leak Alarm, and T2 Gross Test Fail.
3 Miscellaneous - ATG shows T3 Diesel having 15 gallons .91" of water in it.

NOV Number: E0020252464 (Pending)    Issue Date: 9/19/2025    Expiration Date: 11/18/2025    View NOV Form

Tanks Violations
1, 2, 3 Tank monitor does not appear to function properly and requires maintenance. - ATG is not showing passing tank tests. Repair shall be made so ATG provides passing tank tests.

NOV Number: E0020253028 (Pending)    Issue Date: 11/13/2025    Expiration Date: 1/12/2026    View NOV Form

Tanks Violations
1, 2 Miscellaneous - ATG is in alarm Tank 1 Leak Alarm, Tank 2 Leak Alarm, and Tank 2 Gross Test Fail.
1, 2 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - If multiple forms of overfill are installed they all shall be tested every three years. Ball floats need triannual testing. Passing results shall be entered on OSFM portal. Section 175.405 Spill Containment and Overfill Prevention Equipment c) Overfill prevention equipment must be inspected at installation, immediately after any repairs, and at least once every three years, and the inspection shall meet the following criteria: 1) At a minimum, the inspection must ensure that overfill prevention equipment is set to activate at the correct level specified in subsection (a); 2) The overfill prevention equipment will activate when the regulated substance reaches that level; and 3) Inspections must be conducted in accordance with inspection requirements developed by the manufacturer.
1, 2, 3 Precision tank test required. - ATG has been in multiple tank alarms since the last precision tank test and the ATG shows water in all three tanks. A precision tank test is required to ensure the tanks are not leaking.
1, 2 Triennial spill prevention equipment testing not completed. - Section 175.405 Spill Containment and Overfill Prevention Equipment b) Owners and operators of UST systems with spill and overfill prevention equipment must meet the requirements of subsections (b) and (c) and shall ensure the equipment is operating properly and will prevent releases to the environment. Spill prevention equipment (such as a catchment basin, spill bucket, or other spill containment device) must prevent releases to the environment by being tested at installation, immediately after any repairs, and at least once every three years to ensure the equipment is liquid tight

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/20/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date: 11/13/2025
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2025 9/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/18/2025 9/18/2026
Overfill Prev Device Ball Float Vent Valve OPW 53 9/13/2022 9/13/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2025 9/18/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/13/2022 9/13/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/18/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/17/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/20/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date: 11/13/2025
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/23/2025 9/23/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/18/2025 9/18/2026
Overfill Prev Device Ball Float Vent Valve OPW 53 9/13/2022 9/13/2025
Overfill Prev Device Overfill Drop Tube Valve 9/18/2025 9/18/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/13/2022 9/13/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/18/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/17/2025



Tank Number 3

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/20/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date: 11/13/2025
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/18/2025 9/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/18/2025 9/18/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 9/18/2025 9/18/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/18/2025 9/18/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/18/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/17/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found