Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2023371
Status: Active
Facility Name: West Chicago Citgo
Address: 250 S. Neltnor Blvd.
West Chicago, IL 60185
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003363
Green Tag Issue Date: 11/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Amirali Sayani
Owner Address: 1100 Chetwood Drive
Carol Stream, IL 60188
Owner Status: Current Owner
Purchase Date: 11/1/1984
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/5/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/12/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031445 Sayani, Amirali Current Owner 11/1/1984
U0013462 Shah, Nadir Former Owner 6/1/2007

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250313 (Pending)    Issue Date: 2/5/2025    Expiration Date: 4/6/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

NOV Number: E0020250314 (Pending)    Issue Date: 2/5/2025    Expiration Date: 4/6/2025    View NOV Form

Tanks Violation
1, 2 Miscellaneous - ATG is in alarm. T1 Gross Test Fail, T2 Leak Alarm, and T2 Gross Test Fail.
3 Miscellaneous - ATG shows T3 Diesel having 15 gallons .91" of water in it.
1 Overfill prevention equipment does not appear to function properly. - T1 premium overfill drop tube does not appear to function properly. The flapper valve is sticking in to the center of the tube. Repair shall be made and drop tube retested.
1, 2, 3 Precision tank test required.
1, 2, 3 Required monthly tank leak test records not available. - Multiple months do not have passing tank tests.
1, 2 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/20/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/9/2024 9/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/9/2024 9/9/2025
Overfill Prev Device Ball Float Vent Valve OPW 53 9/13/2022 9/13/2025
Overfill Prev Device Overfill Drop Tube Valve 3/14/2025 3/14/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/13/2022 9/13/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/9/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/20/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/9/2024 9/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/9/2024 9/9/2025
Overfill Prev Device Ball Float Vent Valve OPW 53 9/13/2022 9/13/2025
Overfill Prev Device Overfill Drop Tube Valve 11/16/2023 11/16/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/13/2022 9/13/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/9/2024



Tank Number 3

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/20/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 9/9/2024 9/9/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/9/2024 9/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/9/2024 9/9/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 9/13/2022 9/13/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/13/2022 9/13/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/9/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found