Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2023135
Status: Active
Facility Name: BP Lewis and Sunset
Address: 2201 N. Lewis Avenue
Waukegan, IL 60087
County: Lake
Property Parcel: 08-08-214-012
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00867
Green Tag Issue Date: 4/7/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: St. Louis Food Mart, Inc.
Owner Address: 2201 N. Lewis Ave.
Waukegan, IL 60087
Owner Status: Current Owner
Purchase Date: 6/1/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/17/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/7/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039281 St. Louis Food Mart, Inc. Current Owner 6/1/2017
U0023084 Graham Enterprise, Inc. Former Owner 4/28/2009
U0000552 BP Products North America, Inc. Former Owner 1/1/1988

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
89-2008 Eligible 3/13/1997 4/15/1997 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/11/1982 Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date: 5/11/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/11/1982 Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date: 5/11/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 5/11/1982 Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date: 5/11/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/19/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/6/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/6/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/10/2025 2/10/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/10/2025 2/10/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/20/2025 1/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 1/20/2025 1/20/2026
Overfill Prev Device Overfill Drop Tube Valve 1/20/2025 1/20/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/20/2025 1/20/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 11/30/2020
Tank Steel Single Wall Precision Test (Tank) Pass 2/10/2025



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/19/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/6/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/6/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/10/2025 2/10/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/10/2025 2/10/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/20/2025 1/20/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 1/20/2025 1/20/2026
Overfill Prev Device Overfill Drop Tube Valve 1/20/2025 1/20/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/20/2025 1/20/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 11/30/2020
Tank Steel Single Wall Precision Test (Tank) Pass 2/10/2025



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/19/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/6/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/6/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/10/2025 2/10/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/10/2025 2/10/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/10/2025 2/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 1/20/2025 1/20/2026
Overfill Prev Device Overfill Drop Tube Valve 1/20/2025 1/20/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/20/2025 1/20/2028
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 1/11/2024
Tank Steel Single Wall Precision Test (Tank) Pass 2/10/2025



Tank Number 7

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1988
OSFM First Notify Date: 8/29/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1957 Red Tag Issue Date:
Last Used Date: 5/10/1982 Fee Due: $0.00
Product Date: 1/1/1957

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1988
OSFM First Notify Date: 8/29/1994 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1954 Red Tag Issue Date:
Last Used Date: 5/10/1982 Fee Due: $0.00
Product Date: 1/1/1954

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1988
OSFM First Notify Date: 8/29/1994 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1988
OSFM First Notify Date: 8/29/1994 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found