Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2022900
Status: Active
Facility Name: R & S MiniMart
Address: 5901 S. Pulaski Road
Chicago, IL 60629
County: Cook
Property Parcel: 1914300020000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002280
Green Tag Issue Date: 6/12/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Wael Shehayber
Owner Address: 10300 S. 75th Ct.
Palos Hills, IL 60465
Owner Status: Current Owner
Purchase Date: 1/23/2009
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/2/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/12/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035640 Shehayber, Wael Current Owner 1/23/2009
U0023834 BP Amoco Former Owner 4/13/1995
U0027493 Amoco Oil Company Former Owner 1/1/1972
U0000552 BP Products North America, Inc. Former Owner 1/1/1972
U0035189 PAV 2, LLC, Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
09-0340 Eligible 8/27/2009 9/18/2009 $10,000
09-1155 Eligible 5/1/2013 6/20/2013 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/6/2017
OSFM First Notify Date: 9/22/1988 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 3/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 4/1/2015 4/1/2018
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/22/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 3/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 11/28/2024 11/28/2027
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/8/2024 5/8/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 5/8/2024 5/8/2025
Overfill Prev Device Overfill Drop Tube Valve 12/30/2022 12/30/2025
Piping Fiberglass Double Wall N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping STP/Tanktop Sump containment FRP 12/30/2022 12/30/2025
Leak Detect - Piping Sump Sensor 5/8/2024 5/8/2025
Spill Contain Device Single Wall Spill Bucket 12/30/2022 12/30/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Fail 9/9/2021
Piping Fiberglass Double Wall Precision Test (Piping) Pass 9/23/2021
Piping Steel Single Wall Piping Precision Test (Piping) Fail 9/9/2021



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/8/2024 5/8/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 5/8/2024 5/8/2025
Overfill Prev Device Overfill Drop Tube Valve 12/30/2022 12/30/2025
Piping Fiberglass Double Wall N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping STP/Tanktop Sump containment FRP 12/30/2022 12/30/2025
Leak Detect - Piping Sump Sensor 5/8/2024 5/8/2025
Spill Contain Device Single Wall Spill Bucket 12/30/2022 12/30/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 3/12/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 5/12/2020



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 52 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/8/2024 5/8/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 5/8/2024 5/8/2025
Overfill Prev Device Overfill Drop Tube Valve 3/25/2024 3/25/2027
Piping Fiberglass Double Wall N/A N/A
Piping STP/Tanktop Sump containment FRP 12/30/2022 12/30/2025
Leak Detect - Piping Sump Sensor 5/8/2024 5/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/8/2024 7/8/2025
Spill Contain Device Double Wall Spill Bucket 3/25/2024 3/25/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 1/1/1952 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1961 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser UDC Sump containment FRP 3/25/2024 3/25/2027
Leak Detect - Piping Sump Sensor 5/8/2024 5/8/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser UDC Sump containment FRP 3/25/2024 3/25/2027
Leak Detect - Piping Sump Sensor 5/8/2024 5/8/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser UDC Sump containment FRP 3/25/2024 3/25/2027
Leak Detect - Piping Sump Sensor 5/8/2024 5/8/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser UDC Sump containment FRP 1/9/2020 1/9/2023
Leak Detect - Piping Sump Sensor 2/13/2020 2/13/2021

MFD Motorfuel Dispensing Forms

No Forms Found