Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2022856
Status: Active
Facility Name: Westchester 1950 Real Estate, Inc.
Address: 1950 S. Manheim Road
Westchester, IL 60154
County: Cook
Property Parcel: 15-20-416-075-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002641
Green Tag Issue Date: 1/10/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Westchester 1950 Real Estate, Inc.
Owner Address: 1950 S. Mannheim Rd.
Westchester, IL 60154
Owner Status: Current Owner
Purchase Date: 9/29/2023
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/10/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041467 Westchester 1950 Real Estate, Inc. Current Owner 9/29/2023
U0037738 Geo Gasmart, Inc. Former Owner 12/31/2013
U0031155 Eby, George Former Owner 12/31/2013
U0023834 BP Amoco Former Owner 4/13/1995
U0027493 Amoco Oil Company Former Owner 1/1/1971
U0000552 BP Products North America, Inc. Former Owner 1/1/1971
U0031155 Eby, George Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250823 (Pending)    Issue Date: 3/28/2025    Expiration Date: 5/27/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - PLEASE REPAIR INTERCOM
Facility Miscellaneous - Safety switch needs to be tested every year

NOV Number: E0020250824 (Pending)    Issue Date: 3/28/2025    Expiration Date: 5/27/2025    View NOV Form

Tanks Violation
Facility A/B operator retraining required as a result of issuance of the Notice of Violation - NO CURRENT A/B CERTIFICATE ON SITE
5, 6, 7 Annual electronic line leak detector test not completed.
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
5, 6, 7 Annual leak detection certification not completed (Required annually).
Facility Facility Operation and Maintenance Plan not updated to new requirements. - NEW OWNER
Facility Financial responsibility must be reported yearly - https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility
5, 6, 7 Line interstitial sensor functional test not accomplished (Required annually).
5, 6, 7 Line leak detection equipment in alarm or failed test, must repair or replace. - sensor under dispenser 7/8
Facility Missing copies of 30 day Walkthrough Inspection Report.
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Missing copy of emergency instructions or emergency procedures plan - NEW OWNERS INFORMATION
5, 6, 7 Monthly line interstitial sensor records not available.
5, 6, 7 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Due by 4-20-2025
5, 6, 7 Required monthly tank interstitial sensor records not available.
5, 6, 7 Required monthly tank leak test records not available.
5, 6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
Facility Submit Notification Form For Ownership Change - https://webapps.sfm.illinois.gov/USTPortal/NotificationForm
6 Tank interstitial sensors in alarm or failed test, must repair or replace.
5, 6, 7 Tank precision test required.
5, 6, 7 Triennial spill prevention equipment testing not completed.
5, 6, 7 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - All the STP sumps and all the dispenser sumps
5, 6, 7 Water in dispenser containment with interstitial sensors - Remove water and repair containments to prevent water ingress - Dispenser 7/8

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
97-1484 8/12/1997 Removal Log

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/12/1997
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/12/1997
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/12/1997
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/12/1997
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/27/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/14/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/14/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/31/2025 3/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 3/31/2025 3/31/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 3/31/2025 3/31/2026
Overfill Prev Device Overfill Drop Tube Valve 3/31/2025 3/31/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/31/2025 3/31/2028
Leak Detect - Piping Sump Sensor 3/31/2025 3/31/2026
Spill Contain Device Single Wall Spill Bucket 3/31/2025 3/31/2028
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/31/2025
Tank Fiberglass Double Wall Owens Corning Brine Filled Precision Test (Tank) Pass 3/31/2025



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/27/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/14/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/14/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/31/2025 3/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 3/31/2025 3/31/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 4/25/2023 4/25/2024
Overfill Prev Device Overfill Drop Tube Valve 3/31/2025 3/31/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/31/2025 3/31/2028
Leak Detect - Piping Sump Sensor 3/31/2025 3/31/2026
Spill Contain Device Single Wall Spill Bucket 3/31/2025 3/31/2028
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/31/2025
Tank Fiberglass Double Wall Owens Corning Brine Filled Precision Test (Tank) Pass 3/31/2025



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/27/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/14/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/14/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/31/2025 3/31/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root EMC with CSLD 3/31/2025 3/31/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 3/31/2025 3/31/2026
Overfill Prev Device Overfill Drop Tube Valve 3/31/2025 3/31/2028
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/31/2025 3/31/2028
Leak Detect - Piping Sump Sensor 3/31/2025 3/31/2026
Spill Contain Device Single Wall Spill Bucket 3/31/2025 3/31/2028
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/31/2025
Piping Fiberglass Double Wall Precision Test (Piping) Pass 4/20/2022
Tank Fiberglass Double Wall Owens Corning Brine Filled Precision Test (Tank) Pass 3/31/2025



Tank Number 8

Capacity: 800 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/19/2003
OSFM First Notify Date: 10/27/1997 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 8/21/1997 Red Tag Issue Date:
Last Used Date: 2/1/2003 Fee Due: $0.00
Product Date: 8/21/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/31/2025 3/31/2028
Leak Detect - Piping Sump Sensor 3/31/2025 3/31/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/31/2025 3/31/2028
Leak Detect - Piping Sump Sensor 3/31/2025 3/31/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/31/2025 3/31/2028
Leak Detect - Piping Sump Sensor 3/31/2025 3/31/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/31/2025 3/31/2028
Leak Detect - Piping Sump Sensor 4/25/2023 4/25/2024

MFD Motorfuel Dispensing Forms

No Forms Found