Facility Details
Facility Number:
2022805
Status:
Active
Facility Name:
2138 Homewood, Inc.
Address:
2138 W. 183rd Street Homewood, IL 60430
County:
Cook
Property Parcel:
29-31-315-012-0000
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA00333
Green Tag Issue Date:
7/22/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
2138 Property, LLC
Owner Address:
2138 183rd Street Homewood, IL 60430
Owner Status:
Current Owner
Purchase Date:
5/26/2022
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
6/2/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
7/22/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0040717
2138 Property, LLC
Current Owner
5/26/2022
U0039081
Abu-laila, Saleh
Former Owner
10/3/2017
U0038373
S&S Mobil 1, Incorporated
Former Owner
4/28/2014
U0037402
Laila, Saleh
Former Owner
4/28/2014
U0030104
Guglielmi, Peter
Former Owner
9/1/2001
U0000552
BP Products North America, Inc.
Former Owner
12/31/1967
U0023834
BP Amoco
Former Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00858-2025UPG
Upgrade
Approved / Issued
7/8/2025
7/8/2025
1/8/2026
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
89-0429
Eligible
7/25/1996
8/29/1996
$50,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
500
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/1/1989
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
33
Abandoned Date:
Install Date:
1/1/1956
Red Tag Issue Date:
Last Used Date:
4/1/1989
Fee Due:
$0.00
Product Date:
1/1/1956
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/1/1989
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
1/1/1963
Red Tag Issue Date:
Last Used Date:
4/1/1989
Fee Due:
$0.00
Product Date:
1/1/1963
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/1/1989
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
15
Abandoned Date:
Install Date:
1/1/1974
Red Tag Issue Date:
Last Used Date:
4/1/1989
Fee Due:
$0.00
Product Date:
1/1/1974
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/1/1989
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
15
Abandoned Date:
Install Date:
1/1/1974
Red Tag Issue Date:
Last Used Date:
4/1/1989
Fee Due:
$0.00
Product Date:
1/1/1974
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/12/2022
OSFM
First Notify Date:
5/3/1989
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
5/1/1989
Red Tag Issue Date:
Last Used Date:
9/1/2019
Fee Due:
$0.00
Product Date:
5/1/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
10/1/2018
10/1/2019
Corrosion Prot - Tank
Impressed Current Cathodic Protection
10/1/2018
10/1/2019
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
10/1/2018
10/1/2019
Leak Detect - Tank
Automatic Tank Gauging Gilbarco EMC with CSLD
10/1/2018
10/1/2019
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/13/2022
OSFM
First Notify Date:
5/3/1989
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
5/1/1989
Red Tag Issue Date:
Last Used Date:
9/1/2019
Fee Due:
$0.00
Product Date:
5/1/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
10/1/2018
10/1/2019
Corrosion Prot - Tank
Impressed Current Cathodic Protection
10/1/2018
10/1/2019
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
10/1/2018
10/1/2019
Leak Detect - Tank
Automatic Tank Gauging Gilbarco EMC with CSLD
10/1/2018
10/1/2019
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
12000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
1/13/2022
OSFM
First Notify Date:
5/3/1989
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
5/1/1989
Red Tag Issue Date:
Last Used Date:
9/1/2019
Fee Due:
$0.00
Product Date:
5/1/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
10/1/2018
10/1/2019
Corrosion Prot - Tank
Impressed Current Cathodic Protection
10/1/2018
10/1/2019
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
10/1/2018
10/1/2019
Leak Detect - Tank
Automatic Tank Gauging Gilbarco EMC with CSLD
10/1/2018
10/1/2019
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
560
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/10/2018
OSFM
First Notify Date:
5/3/1989
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
5/1/1989
Red Tag Issue Date:
Last Used Date:
1/1/2009
Fee Due:
$0.00
Product Date:
5/1/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
Corrosion Prot - Tank
Impressed Current Cathodic Protection
Leak Detect - Piping
Gravity Feed
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Gilbarco EMC with CSLD
Overfill Prev Device
Less than 25 gallon fills
N/A
N/A
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
2/7/2023
Abandoned Material:
Current Age:
3
Abandoned Date:
Install Date:
2/23/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
1/22/2025
1/22/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
1/22/2025
1/22/2026
Overfill Prev Device
Overfill Drop Tube Valve
1/23/2025
1/23/2028
Piping
Flexible Double Wall NUPI Smartflex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
1/23/2025
1/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
1/22/2025
1/22/2026
Spill Contain Device
Single Wall Spill Bucket
1/23/2025
1/23/2028
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall NUPI Smartflex
Precision Test (Piping)
Pass
1/22/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
1/31/2023
Tank Number 10
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
2/7/2023
Abandoned Material:
Current Age:
3
Abandoned Date:
Install Date:
2/23/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
1/22/2025
1/22/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
1/22/2025
1/22/2026
Overfill Prev Device
Overfill Drop Tube Valve
1/23/2025
1/23/2028
Piping
Flexible Double Wall NUPI Smartflex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
1/23/2025
1/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
1/22/2025
1/22/2026
Spill Contain Device
Single Wall Spill Bucket
1/23/2025
1/23/2028
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall NUPI Smartflex
Precision Test (Piping)
Pass
1/22/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
1/31/2023
Tank Number 11
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
2/7/2023
Abandoned Material:
Current Age:
3
Abandoned Date:
Install Date:
2/23/2022
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Other Non-vented check valve
N/A
N/A
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors With Monitor
1/22/2025
1/22/2026
Overfill Prev Device
Overfill Drop Tube Valve
7/9/2025
7/9/2028
Piping
Flexible Double Wall NUPI Smartflex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
1/23/2025
1/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
1/22/2025
1/22/2026
Spill Contain Device
Double Wall Spill Bucket
7/9/2025
7/9/2028
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall NUPI Smartflex
Precision Test (Piping)
Pass
1/22/2025
Tank
Fiberglass Double Wall XERXES
Precision Test (Tank)
Pass
1/31/2023
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
1/23/2025
1/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
1/22/2025
1/22/2026
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
1/23/2025
1/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
1/22/2025
1/22/2026
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
1/23/2025
1/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
1/22/2025
1/22/2026
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
1/23/2025
1/23/2028
Leak Detect - Piping
Sump Sensor with positive shutdown
1/22/2025
1/22/2026
Name\ID 9/10
Status:
Removed
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
Facility Number
Name
City
Received Date
Letter
2022805
2138 Homewood, Inc.
Homewood
02/01/2023
Letter
Form