Division of Petroleum & Chemical Safety

 
Pay Tank Fees Online Print Detail Page Export to Excel

Facility Details

Facility Number: 2022748
Status: Active
Facility Name: Amoco Oil Station #15680
Address: 2401 Sanders Road Northbrook, IL 60025
County: Cook
Property Parcel: 04-19-201-020-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003295
Green Tag Issue Date: 12/20/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: 2401 Willow Real Estate, LLC
Owner Address: 100 Tri State International, Suite 100 Lincolnshire, IL 60069
Owner Status: Current Owner
Purchase Date: 3/3/2009
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/9/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/20/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035104 2401 Willow Real Estate, LLC Current Owner 3/3/2009
U0023834 BP Amoco Former Owner 4/12/1995
U0027493 Amoco Oil Company Former Owner 1/1/1990
U0000552 BP Products North America, Inc. Former Owner 1/1/1990

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252812 (Pending)    Issue Date: 10/22/2025    Expiration Date: 12/21/2025    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

NOV Number: E0020252813 (Pending)    Issue Date: 10/22/2025    Expiration Date: 12/21/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain 2 years on site with other annual testing documentation.
9 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (interstitial sensors/ATG) not completed. Testing shall be completed and submitted to OSFM.
9 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (leak detectors and/or interstitial sensors) not completed. Testing shall be performed.
10 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (interstitial sensors/ATG) not completed. Testing shall be completed and submitted to OSFM.
10 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (leak detectors and/or interstitial sensors) not completed. Testing shall be performed.
11 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (interstitial sensors/ATG) not completed. Testing shall be completed and submitted to OSFM.
11 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (leak detectors and/or interstitial sensors) not completed. Testing shall be performed.
12 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (interstitial sensors/ATG) not completed. Testing shall be completed and submitted to OSFM.
12 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (leak detectors and/or interstitial sensors) not completed. Testing shall be performed.
9, 10, 11, 12 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated, or missing, the cover and supporting components that are defective shall be replaced. SPECIFICALLY ALL STP LIDS ARE MISSING HANDLES, AND THE REGULAR TANK, CLOSEST TO STORE, STP RING IS DAMAGED/OUT OF ROUND.
Facility Miscellaneous - EMERGENCY STOP SWITCHES ARE NOT ALL LABELED, SPECIFICALLY THE TWO OUTSIDE ON BUILDING, AND ONE IS BEHIND THE ICE MACHINE AND NOT ACCESSIBLE. LABEL BOTH AND MAKE ACCESSIBLE.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and 2 years of documentation maintained on site. 30-Day Walkthrough Inspection form available at www.sfm.illinois.gov. The form must be filled out by an A/B Operator, you must, initial each box that applies, date the form each month to ensure it is being done every 30 days, and the A/B operator must print and sign their name at the bottom. If more than one A/B operator fills out the form, then each must print and sign name at the bottom. NONE ARE DATED AND SOME DONE BY "C" OPERATOR.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and 2 years documentation maintained on site.
9, 10, 11, 12 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Triennial inspection of overfill device (drop tube valve or overfill alarm) has not been completed. Testing shall be completed with passing results and uploaded to OSFM website.
9, 10, 11, 12 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Provide documentation that annual testing of all shear valves has been conducted and passed. Must maintain 2 years of inspection reports.
9, 10, 11, 12 Triennial spill prevention equipment testing not completed. - Triennial inspection/testing of spill bucket(s) has not been completed. Testing shall be completed with passing results uploaded to OSFM.
9, 10, 11, 12 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - Triennial testing for qualifying STP/dispenser piping containment sump(s) not completed. Testing shall be completed and submitted to OSFM.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
06-1590 12/19/2006 Removal Log 01743-2006REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
90-1578 Eligible 9/28/1998 11/18/1998 $10,000
06-1590 Eligible 9/19/2007 9/25/2007 $10,000
06-1590 Eligible 1/5/2009 1/30/2009 $10,000
Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 500 Used Oil Removed Federal $0.00 06/12/1990 - REM
2 6000 Gasoline Removed Federal $0.00 06/12/1990 - REM
3 6000 Gasoline Removed Federal $0.00 06/12/1990 - REM
4 8000 Gasoline Removed Federal $0.00 06/12/1990 - REM
5 12000 Gasoline Removed Federal $0.00 12/19/2006 - REM
6 12000 Gasoline Removed Federal $0.00 12/19/2006 - REM
7 12000 Gasoline Removed Federal $0.00 12/19/2006 - REM
8 550 Used Oil Removed Federal $0.00 03/24/1995 - REM
9 14000 Gasoline - Regular Currently in use Federal $0.00
10 6000 Gasoline - Premium Currently in use Federal $0.00
11 10000 Gasoline - Regular Currently in use Federal $0.00
12 10000 Diesel Fuel Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
3/4 Active
5/6 Active
9/10 Active
7/8 Active
11/12 Active

MFD Motorfuel Dispensing Forms

No Forms Found