Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021821
Status: Active
Facility Name: Ginoob, Inc. d/b/a Amstar
Address: 5035 W. Division Street
Chicago, IL 60651
County: Cook
Property Parcel: 16-04-402-034-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000534
Green Tag Issue Date: 4/18/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Global Gas & Oil Corp.
Owner Address: 340 Jackson Ave.
Glencoe, IL 60022
Owner Status: Current Owner
Purchase Date: 11/1/2013
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/11/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/10/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034167 Global Gas & Oil Corp. Current Owner 11/1/2013
U0037705 Ginoob, Inc. Former Owner 10/1/2014
U0026871 A & H Gas, Inc. Former Owner 9/1/1997
U0008147 Jubilee Oil Co Former Owner 12/31/1967
U0034167 Global Gas & Oil Corp. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250183 (Pending)    Issue Date: 1/23/2025    Expiration Date: 3/24/2025    View NOV Form

Tanks Violation
Facility Missing copies of 30 day Walkthrough Inspection Report. - Not recorded for previous 2 years and last entry November 2024
1, 2, 3 Monthly impressed current log not available or maintained. - https://sfm.illinois.gov/content/dam/soi/en/web/sfm/sfmdocuments/documents/monthlyimpressedcurrentlog.pdf
1, 2, 3 Monthly impressed current system log not available or maintained. - https://sfm.illinois.gov/content/dam/soi/en/web/sfm/sfmdocuments/documents/monthlyimpressedcurrentlog.pdf
1, 2, 3 Required monthly tank leak test records not available. - Need 2 years worth of CSLD reports
1, 2, 3 Tank precision test required. - If can not provide 2 years of passing tapes.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-2403 Eligible 8/4/1998 9/4/1998 $10,000
02-0220 Eligible 6/2/2004 6/28/2004 $10,000
20191071 Eligible 9/21/2021 9/24/2021 $5,000 Letter
19972403 Eligible 11/15/2023 11/16/2023 $10,000 Letter
20020220 Eligible 11/15/2023 11/16/2023 $10,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Flex Connector 11/22/2024 11/22/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/22/2022 6/22/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/22/2024 11/22/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/11/2024 11/11/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 11/11/2024 11/11/2025
Overfill Prev Device Overfill Drop Tube Valve 4/18/2023 4/18/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/22/2022 6/22/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/11/2024
Tank Steel Single Wall Precision Test (Tank) Pass 4/18/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Flex Connector 11/22/2024 11/22/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/22/2022 6/22/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/22/2024 11/22/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/11/2024 11/11/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 11/11/2024 11/11/2025
Overfill Prev Device Overfill Drop Tube Valve 6/22/2022 6/22/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/22/2022 6/22/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/11/2024
Tank Steel Single Wall Precision Test (Tank) Pass 4/18/2023



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Flex Connector 11/22/2024 11/22/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/22/2022 6/22/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/22/2024 11/22/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/11/2024 11/11/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD 11/11/2024 11/11/2025
Overfill Prev Device Overfill Drop Tube Valve 6/22/2022 6/22/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/22/2022 6/22/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/11/2024
Tank Steel Single Wall Precision Test (Tank) Pass 4/18/2023



Tank Number 4

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/5/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 48 Abandoned Date: 11/19/2019
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: 11/6/2017 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/1/2018 1/1/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/1/2018 1/1/2019
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found