Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021476
Status: Active
Facility Name: Rockbuild Enterprises, Inc. d/b/a Kedzie Auto Service
Address: 5301 S. Kedzie Chicago, IL 60632
County: Cook
Property Parcel: 19-12-316-041-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA02194
Green Tag Issue Date: 8/27/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Rockbuild Enterprises, Inc.
Owner Address: 3720 Albert Lane Long Grove, IL 60047
Owner Status: Current Owner
Purchase Date: 12/15/2020
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 7/3/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/27/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034774 Rockbuild Enterprises, Inc. Current Owner 12/15/2020
U0016367 Wholesale Oil Company Former Owner 1/1/1985
U0028367 Kedzie Auto Service Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00221-2024INS Install Extension Granted 2/22/2024 2/26/2024 2/27/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
22-0402 5/10/2022 Removal Log 00468-2022REM
22-0409 5/11/2022 Removal Log 00468-2022REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20220402 Eligible 1/20/2023 1/24/2023 $5,000 Letter
20171069 Eligible 1/20/2023 1/24/2023 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/10/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 2/28/2017 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/28/2013 2/28/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/5/2016 10/5/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/10/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/5/2003 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/28/2013 2/28/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/20/2015 10/20/2016
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 33 Abandoned Date: 10/4/2006
Install Date: Red Tag Issue Date:
Last Used Date: 12/20/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/2022
OSFM First Notify Date: 4/10/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 33 Abandoned Date: 10/4/2006
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Waste Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 33 Abandoned Date: 10/4/2006
Install Date: Red Tag Issue Date:
Last Used Date: 12/20/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2025 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 5/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2025 8/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 8/21/2025 8/21/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2025 8/21/2026
Overfill Prev Device Overfill Drop Tube Valve 8/21/2025 8/21/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026
Spill Contain Device Single Wall Spill Bucket 4/22/2024 4/22/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/21/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/21/2025



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2025 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 5/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2025 8/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 8/21/2025 8/21/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2025 8/21/2026
Overfill Prev Device Overfill Drop Tube Valve 8/21/2025 8/21/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026
Spill Contain Device Single Wall Spill Bucket 4/22/2024 4/22/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/21/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/21/2025



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2025 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 5/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2025 8/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 8/21/2025 8/21/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/21/2025 8/21/2026
Overfill Prev Device Overfill Drop Tube Valve 8/21/2025 8/21/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026
Spill Contain Device Single Wall Spill Bucket 4/22/2024 4/22/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/21/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/21/2025

Dispenser Information



Name\ID Dispenser 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026



Name\ID Dispenser 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026



Name\ID Dispenser 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026



Name\ID Dispenser 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/22/2024 4/22/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/21/2025 8/21/2026

MFD Motorfuel Dispensing Forms