Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2021424
Status:
Closed
Facility Name:
JMS Auto Service, Inc.
Address:
5837 South Madison
Hinsdale, IL 60521
County:
Du Page
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
P000271
Green Tag Issue Date:
11/6/2014
Green Tag Expiration Date:
12/31/2016
Owner Details
Owner Name:
South Madison, LLC
Owner Address:
0666B SW Palatine Hill Rd.
Portland, OR 97219
Owner Status:
Current Owner
Purchase Date:
6/1/2009
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
12/4/2015
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
11/6/2014
12/31/2016
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0035397
South Madison, LLC
Current Owner
6/1/2009
U0008842
Lake Shore Petroleum Corporation
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
16-1096
11/22/2016
Removal Log
01405-2016REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20161096
Eligible
12/27/2016
12/27/2016
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/22/2016
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/21/2016
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
11/6/2014
11/6/2017
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/8/2016
6/8/2017
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300i
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall Containment Solutions
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
SIR and Prec Tightness Testing
Precision Test (Tank)
Pass
11/15/2010
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/22/2016
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/21/2016
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
11/6/2014
11/6/2017
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/8/2016
6/8/2017
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300i
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall Containment Solutions
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
SIR and Prec Tightness Testing
Precision Test (Tank)
Pass
11/15/2010
Tank Number 3
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/22/2016
OSFM
First Notify Date:
4/21/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/21/2016
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
11/6/2014
11/6/2017
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/8/2016
6/8/2017
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300i
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall Containment Solutions
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
SIR and Prec Tightness Testing
Precision Test (Tank)
Pass
11/15/2010
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found