Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021205
Status: Active
Facility Name: Circle K #6807
Address: 10 Skokie Highway Highland Park, IL 60035
County: Lake
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA000880
Green Tag Issue Date: 4/30/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: RDK Ventures LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures LLC Current Owner 1/7/2010
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0027449 Equilon Enterprises, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-0700 Eligible 10/23/1998 12/1/1998 $10,000
08-0779 Eligible 10/1/2008 11/20/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/19/1996
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 11/1/1978 Red Tag Issue Date:
Last Used Date: 4/15/1996 Fee Due: $0.00
Product Date: 11/1/1978

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/19/1996
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 11/1/1978 Red Tag Issue Date:
Last Used Date: 4/15/1996 Fee Due: $0.00
Product Date: 11/1/1978

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/19/1996
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/1/1970 Red Tag Issue Date:
Last Used Date: 4/15/1996 Fee Due: $0.00
Product Date: 11/1/1970

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/19/1996
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/15/1996 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 500 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Pre 1974 CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 1/1/1902 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 6

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/7/1997 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/25/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/25/1996

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/21/2026 8/21/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 6/23/2026 6/23/2027
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/23/2026 6/23/2027
Overfill Prev Device Overfill Drop Tube Valve 7/16/2024 7/16/2027
Piping Polyethylene Chase Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Fiberglass Single Wall Piping Ameron Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 7/16/2024 7/16/2027
Tank Fiberglass Brine Filled Double Wall Containment Solutions Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/23/2026
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 8/9/2022
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 9/13/2022
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 5/17/2007



Tank Number 7

Capacity: 15000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/7/1997 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 4/25/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/25/1996

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/23/2026 6/23/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 6/23/2026 6/23/2027
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 8/21/2026 8/21/2027
Overfill Prev Device Overfill Drop Tube Valve 7/16/2024 7/16/2027
Piping Polyethylene Chase Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Fiberglass Single Wall Piping Ameron Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated 7/1/2025 Not applicable
Spill Contain Device Double Wall Spill Bucket 4/16/2025 4/16/2028
Tank Fiberglass Brine Filled Double Wall Containment Solutions Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/23/2026
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 9/2/2022
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 1/8/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 5/17/2007

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms