Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021191
Status: Active
Facility Name: Rolling Meadows Shell, Inc.
Address: 2200 Algonquin Road
Rolling Meadows, IL 60008
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002443
Green Tag Issue Date: 8/20/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Nickolas Kontos
Owner Address: 7024 N. Keeler
Lincolnwood, IL 607122318
Owner Status: Current Owner
Purchase Date: 12/12/2012
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/27/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/20/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036784 Nickolas Kontos Current Owner 12/12/2012
U0035839 2200 Algonquin Rd., Inc. Former Owner 4/1/2010
U0031974 C.N.C. Dynamics, Inc. Former Owner 3/1/2004
U0030306 Capital Development Corporation, Former Owner 11/29/2001
U0027449 Equilon Enterprises, LLC Former Owner 5/1/1970
U0013849 Shell Oil Products Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
01-0400 3/9/2001 Removal Log 02001-2000REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-2423 Eligible 4/15/1999 5/3/1999 $10,000
01-0400 Eligible 10/10/2002 10/22/2002 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/9/2001
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/1/1970 Red Tag Issue Date:
Last Used Date: 3/6/2001 Fee Due: $0.00
Product Date: 5/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/9/2001
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/1/1970 Red Tag Issue Date:
Last Used Date: 3/6/2001 Fee Due: $0.00
Product Date: 5/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/9/2001
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 11/1/1971 Red Tag Issue Date:
Last Used Date: 3/6/2001 Fee Due: $0.00
Product Date: 11/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/25/1998
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 9/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/6/2003 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 11/29/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/27/2023 6/27/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/13/2024 6/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/13/2024 6/13/2025
Overfill Prev Device Overfill Drop Tube Valve 3/18/2022 3/18/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/13/2024 6/13/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 7/8/2020
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 6/13/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/17/2020



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/6/2003 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 11/29/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 6/27/2023 6/27/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/13/2024 6/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 6/13/2024 6/13/2025
Overfill Prev Device Overfill Drop Tube Valve 3/18/2022 3/18/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/13/2024 6/13/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 6/13/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/17/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms