Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021180
Status: Active
Facility Name: Circle K #6800
Address: 4 W. Irving Park Road @ York Bensenville, IL 60106
County: Du Page
Property Parcel: 03-14-213-048
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01608
Green Tag Issue Date: 9/16/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: RDK Ventures LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 1/26/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/16/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures LLC Current Owner 1/7/2010
U0027449 Equilon Enterprises, LLC Former Owner 9/14/1988
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00846-2025UPG Upgrade Approved / Revised 7/7/2025 7/7/2025 1/7/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2022-1104 4/18/2023 Abandonment Log 00094-2023ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-1059 Eligible 10/1/2008 11/19/2008 $15,000
20221104 Eligible 4/26/2023 4/26/2023 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/12/1988
OSFM First Notify Date: 1/5/1987 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/12/1988
OSFM First Notify Date: 1/5/1987 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/12/1988
OSFM First Notify Date: 1/5/1987 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/12/1988
OSFM First Notify Date: 1/5/1987 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/20/1993 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 9/14/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/22/2025 9/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/22/2025 9/22/2026
Overfill Prev Device Overfill Drop Tube Valve 2/5/2025 2/5/2028
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 1/30/2024 1/30/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/9/2021 3/9/2022
Leak Detect - Piping Discriminating Sump Sensor with positive shutdown 1/17/2023 1/17/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/19/2023 12/19/2024
Leak Detect - Piping Sump Sensor with positive shutdown 9/22/2025 9/22/2026
Spill Contain Device Single Wall Spill Bucket 1/30/2024 1/30/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 1/17/2023
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 9/22/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/12/2024



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/20/1993 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 9/14/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/22/2025 9/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/22/2025 9/22/2026
Overfill Prev Device Overfill Drop Tube Valve 2/5/2025 2/5/2028
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 1/30/2024 1/30/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 1/17/2023 1/17/2024
Leak Detect - Piping Sump Sensor with positive shutdown 9/22/2025 9/22/2026
Spill Contain Device Single Wall Spill Bucket 1/30/2024 1/30/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 1/17/2023
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 9/22/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 1/17/2024



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/20/1993 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 4/18/2023
Install Date: 9/14/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/3/2023 3/3/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/17/2023 1/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/7/2021 8/7/2024
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 3/15/2021 3/15/2024
Leak Detect - Piping Sump Sensor 1/17/2023 1/17/2024
Spill Contain Device Single Wall Spill Bucket 3/15/2021 3/15/2024
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 1/17/2023
Tank Fiberglass Single Wall Precision Test (Tank) Fail 12/15/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/30/2024 1/30/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/22/2025 9/22/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/30/2024 1/30/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/22/2025 9/22/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/30/2024 1/30/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/22/2025 9/22/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/30/2024 1/30/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/22/2025 9/22/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/30/2024 1/30/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/22/2025 9/22/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/30/2024 1/30/2027
Leak Detect - Piping Sump Sensor with positive shutdown 11/10/2025 11/10/2026

MFD Motorfuel Dispensing Forms

No Forms Found