Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0040192 |
Fairway Services Enterprise, LLC |
Current Owner |
4/1/2019 |
| U0035735 |
True North Energy, LLC |
Former Owner |
3/8/2010 |
| U0013849 |
Shell Oil Products |
Former Owner |
12/31/1967 |
| U0031151 |
Shell Oil Products US c/o Gilbarco Veeder-Root |
Former Owner |
|
| U0027449 |
Equilon Enterprises, LLC |
Former Owner |
|
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00452-2026ABN |
Abandon in Place |
Approved / Issued |
4/23/2026 |
4/23/2026 |
10/23/2026 |
Documents |
Notice of Violations (Current)
NOV Number:
E0020261183
(Pending)
Issue Date:
5/5/2026
Expiration Date:
7/4/2026
View NOV Form
| Tanks |
Violations |
| 1, 3 |
Annual leak detection certification not completed (Required annually). |
| 1 |
Line interstitial sensor functional test not accomplished (Required annually). - Dispenser sump sensors |
| 1 |
Line interstitial sensor functional test not accomplished (Required annually). - Sump Sensors |
| 3 |
Line interstitial sensor functional test not accomplished (Required annually). - Dispenser sump sensors |
| 3 |
Line interstitial sensor functional test not accomplished (Required annually). - Sump Sensors |
| 1, 3 |
Line leak detection equipment in alarm or failed test, must repair or replace. - Dispensers all have S1 / S2 / and S3 communication errors on tank monitor |
| 1, 3 |
Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. |
NOV Number:
E0020261185
(Pending)
Issue Date:
5/5/2026
Expiration Date:
7/4/2026
View NOV Form
| Tanks |
Violations |
| 1 |
Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Submersible lid / supporrt ring. Large open crack in concrete with an open hole directly into the sump |
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 2026-0278 |
5/5/2026 |
Abandonment Log |
00452-2026ABN |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 94-0249 |
Eligible |
3/27/1998
|
4/13/1998
|
$10,000
|
|
| 08-0910 |
Eligible |
10/1/2008
|
11/18/2008
|
$10,000
|
|
| 20260278 |
Eligible |
7/9/2026
|
7/21/2026
|
$5,000
|
Letter
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
45 |
|
Abandoned Date: |
|
| Install Date: |
12/9/1980 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
5/24/2026 |
5/24/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
5/24/2026 |
5/24/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/28/2023 |
9/28/2026 |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/10/2025 |
3/10/2028 |
Leak Detect - Piping
|
Sump Sensor |
3/10/2025 |
3/10/2028 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
3/10/2025 |
3/10/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall
|
Precision Test (Piping)
|
Pass
|
3/10/2025
|
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Non Ethanol |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
45 |
|
Abandoned Date: |
5/5/2026 |
| Install Date: |
12/9/1980 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
2/4/2025 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/28/2023 |
9/28/2024 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
9/28/2023 |
9/28/2024 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/28/2023 |
9/28/2026 |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/21/2021 |
10/21/2024 |
Leak Detect - Piping
|
Sump Sensor |
10/21/2021 |
10/21/2024 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/28/2021 |
10/28/2024 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Tank
|
Fiberglass Single Wall
|
Precision Test (Tank)
|
Fail
|
2/10/2025
|
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
45 |
|
Abandoned Date: |
|
| Install Date: |
12/9/1980 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
5/24/2026 |
5/24/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
5/24/2026 |
5/24/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/28/2023 |
9/28/2026 |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
3/10/2025 |
3/10/2028 |
Leak Detect - Piping
|
Sump Sensor |
3/10/2025 |
3/10/2028 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
3/10/2025 |
3/10/2028 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall
|
Precision Test (Piping)
|
Pass
|
3/10/2025
|
Tank Number 4
| Capacity: |
550 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
6/25/1996 |
|
OSFM
First Notify Date: |
5/5/1986 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1961 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
6/20/1996 |
|
Fee Due: |
$0.00 |
| Product Date: |
1/1/1961 |
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/10/2025
|
3/10/2028
|
Leak Detect - Piping
|
Sump Sensor |
5/24/2026
|
5/24/2027
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/10/2025
|
3/10/2028
|
Leak Detect - Piping
|
Sump Sensor |
5/24/2026
|
5/24/2027
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/10/2025
|
3/10/2028
|
Leak Detect - Piping
|
Sump Sensor |
5/24/2026
|
5/24/2027
|
Name\ID 7/8
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
3/10/2025
|
3/10/2028
|
Leak Detect - Piping
|
Sump Sensor |
5/24/2026
|
5/24/2027
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.