Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021163
Status: Active
Facility Name: Circle K #6750
Address: 4 Irving Park Road
Roselle, IL 60172
County: Du Page
Property Parcel: 02-03-112-045
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002780
Green Tag Issue Date: 8/15/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1120 W. Warner Rd.
Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/24/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/13/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 1/7/2010
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0027449 Equilon Enterprises, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250258 (Pending)    Issue Date: 1/30/2025    Expiration Date: 3/31/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

NOV Number: E0020250259 (Pending)    Issue Date: 1/30/2025    Expiration Date: 3/31/2025    View NOV Form

Tanks Violation
5, 6, 7 Dispensers - hoses cracked, split or worn and require replacement - The main hose has cracks in it and needs to be replacxed. The dispenser hose should not be used until it is replaced.
Facility Facility Operation and Maintenance Plan not completed or available.
Facility Miscellaneous - Emergency shut off switch at control station needs a sign. 175.210 d) 3) Equipped with an emergency stop at all control stations, which shall be conspicuously marked and readily accessible to the attendant, whether or not the control station is less than 20 feet from any dispenser or a security booth is provided for the attendant. The emergency stop shall be located in a position to allow all dispensing devices to be readily visible to the attendant, or as approved by OSFM. Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters.
Facility Miscellaneous - There is a slight leak from pipe under dispenser 3/4. Repair leak and clean the bottom of the sump.
Facility Missing copy of emergency instructions or emergency procedures plan
5, 6 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Spill and vapor buckets have liquid in them. The bottom of the multi port sump has water in it and should be removed prior to activating sensor.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-1061 Eligible 10/1/2008 11/17/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/1990
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/1990
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/1990
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 1/1/1980 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/11/1990
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/13/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 5/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/24/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/26/2024 9/26/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Drop Tube Valve 10/25/2024 10/25/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 1/5/2024 1/5/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 12/8/2021 12/8/2022
Leak Detect - Piping Discriminating Sump Sensor with positive shutdown 11/21/2022 11/21/2023
Leak Detect - Piping Sump Sensor with positive shutdown 10/12/2023 10/12/2024
Leak Detect - Piping Sump Sensor with positive shutdown 7/17/2024 7/17/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 1/5/2024 1/5/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 9/26/2024



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/13/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 5/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/22/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Drop Tube Valve 10/25/2024 10/25/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 1/5/2024 1/5/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 1/4/2021 1/4/2022
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025
Spill Contain Device Single Wall Spill Bucket 1/5/2024 1/5/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 9/26/2024



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/13/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 5/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/24/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/26/2024 9/26/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/26/2024 9/26/2025
Overfill Prev Device Overfill Drop Tube Valve 9/26/2024 9/26/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 1/5/2024 1/5/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025
Spill Contain Device Double Wall Spill Bucket 8/30/2022 8/30/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 9/26/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 6/9/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/5/2024 1/5/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/5/2024 1/5/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/5/2024 1/5/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/5/2024 1/5/2027
Leak Detect - Piping Sump Sensor 9/26/2024 9/26/2025

MFD Motorfuel Dispensing Forms

No Forms Found