Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021153
Status: Active
Facility Name: Shell Service Station
Address: 517 Mall Drive Schaumburg, IL 60173
County: Cook
Property Parcel: 07-13-400-012-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00062
Green Tag Issue Date: 8/5/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Stambolic, R E, LLC
Owner Address: 300 N. Martingale Rd. Schaumburg, IL 60195
Owner Status: Current Owner
Purchase Date: 5/17/2010
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/7/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/5/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035798 Stambolic, R E, LLC Current Owner 5/17/2010
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0027449 Equilon Enterprises, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251961 (Pending)    Issue Date: 8/5/2025    Expiration Date: 10/4/2025    View NOV Form

Tanks Violations
4, 5, 6, 7 Triennial spill prevention equipment testing not completed.
4, 5, 6, 7 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - All tank tops and UDC's

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2017-0808 10/5/2017 Removal Log 01157-2017REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
02-1557 Eligible 3/19/2003 3/28/2003 $10,000
20170808 Eligible 11/13/2017 11/13/2017 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/5/2017
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 3/26/2013 3/26/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/5/2017 4/5/2018
Leak Detect - Piping Sump Sensor 4/5/2017 4/5/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/5/2017
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 3/26/2013 3/26/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/5/2017 4/5/2018
Leak Detect - Piping Sump Sensor 4/5/2017 4/5/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/5/2017
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 3/26/2013 3/26/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/5/2017 4/5/2018
Leak Detect - Piping Sump Sensor 4/5/2017 4/5/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/5/2017 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 10/13/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/28/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2025 1/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/29/2025 1/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/29/2025 1/29/2026
Overfill Prev Device Overfill Drop Tube Valve 8/25/2022 8/25/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026
Spill Contain Device Double Wall Spill Bucket 7/28/2022 7/28/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/29/2025



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/5/2017 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 10/13/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/28/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2025 1/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/29/2025 1/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/29/2025 1/29/2026
Overfill Prev Device Overfill Drop Tube Valve 8/18/2022 8/18/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026
Spill Contain Device Double Wall Spill Bucket 7/28/2022 7/28/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/29/2025



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/5/2017 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 10/13/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/28/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/29/2025 1/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 1/29/2025 1/29/2026
Overfill Prev Device Overfill Drop Tube Valve 8/18/2022 8/18/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026
Leak Detect - Piping Sump Sensor with positive shutdown 5/9/2025 5/9/2026
Spill Contain Device Double Wall Spill Bucket 7/28/2022 7/28/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/29/2025



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/5/2017 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 10/13/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/28/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/29/2025 1/29/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/29/2025 1/29/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/29/2025 1/29/2026
Overfill Prev Device Overfill Drop Tube Valve 8/18/2022 8/18/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026
Spill Contain Device Double Wall Spill Bucket 7/28/2022 7/28/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 1/29/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2022 7/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/29/2025 1/29/2026