Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021025
Status: Active
Facility Name: Mobil
Address: 1150 North Cicero
Chicago, IL 60651
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000533
Green Tag Issue Date: 4/19/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Methal Fakhoury
Owner Address:
Owner Status: Current Owner
Purchase Date: 6/1/2001
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/23/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/9/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032387 Methal Fakhoury Current Owner 6/1/2001
U0030112 R & S Enterprises, Former Owner 1/1/2001
U0027449 Equilon Enterprises, LLC Former Owner 1/1/1973
U0013849 Shell Oil Products Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
93-2108 3/29/2001 Removal Log 105806

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-2108 Eligible 8/7/1998 9/15/1998 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/29/2001
OSFM First Notify Date: 4/23/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/29/2001
OSFM First Notify Date: 4/23/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/29/2001
OSFM First Notify Date: 4/23/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/28/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 3/1/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/13/2023 12/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/13/2023 4/13/2024
Overfill Prev Device Overfill Drop Tube Valve 4/1/2022 4/1/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/24/2024 1/24/2027
Leak Detect - Piping Sump Sensor 4/13/2023 4/13/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024
Spill Contain Device Single Wall Spill Bucket 4/13/2023 4/13/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 12/13/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/13/2023



Tank Number 5

Capacity: 7000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/28/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 3/1/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/13/2023 4/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/13/2023 4/13/2024
Overfill Prev Device Overfill Drop Tube Valve 4/1/2022 4/1/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/13/2023 4/13/2026
Leak Detect - Piping Sump Sensor 4/14/2023 4/14/2024
Spill Contain Device Single Wall Spill Bucket 4/13/2023 4/13/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 4/13/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/13/2023



Tank Number 6

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/28/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 3/1/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/13/2023 4/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/13/2023 4/13/2024
Overfill Prev Device Overfill Drop Tube Valve 4/1/2022 4/1/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 4/13/2023 4/13/2026
Leak Detect - Piping Sump Sensor 4/14/2023 4/14/2024
Spill Contain Device Single Wall Spill Bucket 4/13/2023 4/13/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 4/13/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/13/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/13/2023 4/13/2026
Leak Detect - Piping Sump Sensor 4/13/2023 4/13/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/13/2023 4/13/2026
Leak Detect - Piping Sump Sensor 4/13/2023 4/13/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/13/2023 4/13/2026
Leak Detect - Piping Sump Sensor 4/13/2023 4/13/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/13/2023 4/13/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID Removed/No Number

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/13/2023 4/13/2026

MFD Motorfuel Dispensing Forms

No Forms Found