Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2020685
Status:
Closed
Facility Name:
North District Shop
Address:
3955 N. Kilpatrick Ave. Chicago, IL 60641
County:
Cook
Property Parcel:
13-22-102-001-0000
Facility Type:
Utility
Owner Type:
Private
Green Tag Decal:
T003848
Green Tag Issue Date:
10/4/2018
Green Tag Expiration Date:
10/5/2020
Owner Details
Owner Name:
Peoples Gas Light & Coke Company
Owner Address:
200 East Randolph Street Chicago, IL 606016302
Owner Status:
Current Owner
Purchase Date:
1/1/1986
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
8/14/2021
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
8/24/2018
12/31/2020
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0011727
Peoples Gas Light & Coke Company
Current Owner
1/1/1986
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2020-0813
9/24/2020
Removal Log
01213-2020REM
2020-0813
9/25/2020
Removal Log
01213-2020REM
2020-0813
10/21/2020
Removal Log
01213-2020REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
99-0733
Eligible
2/22/2000
2/29/2000
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/24/2020
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Current Age:
46
Abandoned Date:
Install Date:
2/1/1974
Red Tag Issue Date:
Last Used Date:
6/29/2020
Fee Due:
$0.00
Product Date:
4/1/1974
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/15/2019
8/15/2020
Leak Detect - Piping
Sump Sensor
8/15/2019
8/15/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
8/15/2019
8/15/2020
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
8/22/2018
8/22/2021
Spill Contain Device
Single Wall Spill Bucket
8/22/2018
8/22/2021
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
8/15/2019
Tank Number 2
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/25/2020
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Current Age:
46
Abandoned Date:
Install Date:
2/1/1974
Red Tag Issue Date:
Last Used Date:
6/29/2020
Fee Due:
$0.00
Product Date:
4/1/1974
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
8/23/2018
8/23/2021
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/15/2019
8/15/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
8/15/2019
8/15/2020
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Double Wall Spill Bucket
8/22/2018
8/22/2021
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Steel Single Wall Piping
Precision Test (Piping)
Pass
8/15/2019
Tank Number 3
Capacity:
6000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/25/2020
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Current Age:
46
Abandoned Date:
Install Date:
2/1/1974
Red Tag Issue Date:
Last Used Date:
6/29/2020
Fee Due:
$0.00
Product Date:
4/1/1974
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
9/28/2018
9/28/2021
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
8/15/2019
8/15/2020
Overfill Prev Device
Overfill Drop Tube Valve
8/22/2018
8/22/2021
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
1000
Petroleum Use:
None
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/28/2020
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
47
Abandoned Date:
4/7/1993
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/28/2020
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
47
Abandoned Date:
4/1/1974
Install Date:
Red Tag Issue Date:
Last Used Date:
4/1/1974
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Does Not Exist
CAS Code:
Regulated Status:
Exempt
Removed Date:
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
47
Abandoned Date:
4/1/1974
Install Date:
Red Tag Issue Date:
Last Used Date:
4/1/1974
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
1000
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Fuel Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
10/21/2020
OSFM
First Notify Date:
11/16/2020
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/31/1973
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found