Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041506 |
St Johns Real Estate, Inc. |
Current Owner |
1/12/2024 |
| U0036558 |
Lake Bluff Petroleum, Inc. |
Former Owner |
6/13/2012 |
| U0035269 |
Alliance Oil Corp. |
Former Owner |
3/27/2009 |
| U0034207 |
A S & K 5, Inc. |
Former Owner |
5/23/2007 |
| U0032773 |
218 Waukegan, Inc., |
Former Owner |
3/24/2005 |
| U0032209 |
Combined Real Estate, LLC |
Former Owner |
7/16/2004 |
| U0007721 |
J & L Oil Co., Inc. |
Former Owner |
9/1/1970 |
| U0036922 |
Ansari, Muhammad |
Former Owner |
|
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 13-0392 |
5/2/2013 |
Removal Log |
00315-2013REM |
| 13-0392 |
5/3/2013 |
Removal Log |
00315-2013REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 13-0392 |
Eligible |
5/1/2013
|
6/25/2013
|
$5,000
|
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
5/3/2013 |
|
OSFM
First Notify Date: |
4/28/1986 |
|
Abandoned Material: |
|
| Current Age: |
42 |
|
Abandoned Date: |
|
| Install Date: |
9/1/1970 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/1/1970 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Cathodic Protection |
12/7/2010 |
12/7/2011 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
12/7/2010 |
12/7/2011 |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
2/28/2008 |
2/28/2013 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/30/2010 |
4/30/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Alarm |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
5/2/2013 |
|
OSFM
First Notify Date: |
4/28/1986 |
|
Abandoned Material: |
|
| Current Age: |
42 |
|
Abandoned Date: |
|
| Install Date: |
9/1/1970 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/1/1970 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Cathodic Protection |
12/7/2010 |
12/7/2011 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
12/7/2010 |
12/7/2011 |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
2/28/2008 |
2/28/2013 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/30/2010 |
4/30/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Alarm |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
5/2/2013 |
|
OSFM
First Notify Date: |
4/28/1986 |
|
Abandoned Material: |
|
| Current Age: |
42 |
|
Abandoned Date: |
|
| Install Date: |
9/1/1970 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/1/1970 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Cathodic Protection |
12/7/2010 |
12/7/2011 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
12/7/2010 |
12/7/2011 |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
2/28/2008 |
2/28/2013 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
4/30/2010 |
4/30/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Alarm |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
6/26/2013 |
|
Abandoned Material: |
|
| Current Age: |
13 |
|
Abandoned Date: |
|
| Install Date: |
5/8/2013 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
6/2/2025 |
6/2/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
6/2/2025 |
6/2/2026 |
|
Overfill Prev Device
|
Overfill Alarm |
6/2/2025 |
6/2/2028 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/2/2025 |
6/2/2028 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
12/4/2024 |
12/4/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
12/4/2024 |
12/4/2027 |
|
Piping
|
Single Wall Transition Sump |
12/4/2024 |
12/4/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
12/4/2024 |
12/4/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/2/2025 |
6/2/2028 |
|
Tank
|
Composite Double Wall Lannon |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
6/2/2025
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC
|
Precision Test (Piping)
|
Pass
|
6/2/2025
|
|
Tank
|
Composite Double Wall Lannon
|
Precision Test (Tank)
|
Pass
|
6/2/2025
|
Tank Number 5
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
6/26/2013 |
|
Abandoned Material: |
|
| Current Age: |
13 |
|
Abandoned Date: |
|
| Install Date: |
5/8/2013 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
6/2/2025 |
6/2/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
6/2/2025 |
6/2/2026 |
|
Overfill Prev Device
|
Overfill Alarm |
6/2/2025 |
6/2/2028 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/2/2025 |
6/2/2028 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
12/4/2024 |
12/4/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
12/4/2024 |
12/4/2027 |
|
Piping
|
Single Wall Transition Sump |
12/4/2024 |
12/4/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
12/4/2024 |
12/4/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/2/2025 |
6/2/2028 |
|
Tank
|
Composite Double Wall Lannon |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron
|
Precision Test (Piping)
|
Pass
|
6/2/2025
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P175SC
|
Precision Test (Piping)
|
Pass
|
6/2/2025
|
|
Tank
|
Composite Double Wall Lannon
|
Precision Test (Tank)
|
Pass
|
6/2/2025
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/3
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
12/4/2024
|
12/4/2027
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/2/2025
|
6/2/2026
|
Name\ID 2/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
12/4/2024
|
12/4/2027
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/2/2025
|
6/2/2026
|
Name\ID 5/7
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
12/4/2024
|
12/4/2027
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/2/2025
|
6/2/2026
|
Name\ID 6/8
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
12/4/2024
|
12/4/2027
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
6/2/2025
|
6/2/2026
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found