Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2020645
Status:
Closed
Facility Name:
Graham Enterprise, Inc.
Address:
8618 US-12
Richmond, IL 60071
County:
McHenry
Property Parcel:
04-21-251-022
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
S001562
Green Tag Issue Date:
6/21/2017
Green Tag Expiration Date:
12/31/2019
Owner Details
Owner Name:
Roadmaster Investment, LLC-118
Owner Address:
750 Bunker Court
Vernon Hills, IL 60061
Owner Status:
Current Owner
Purchase Date:
2/4/2022
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
6/29/2024
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
6/21/2017
12/31/2019
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0040499
Roadmaster Investment, LLC-118
Current Owner
2/4/2022
U0039589
A&E Holding, LLC
Former Owner
6/10/2019
U0023596
KB Oil Company, Inc.
Former Owner
7/20/1994
U0007721
J & L Oil Co., Inc.
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
N/A
12/6/2023
Removal Log
01296-2023REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
95-0823
Eligible
7/5/1995
8/28/1995
$15,000
20230979
Eligible
8/12/2024
8/13/2024
$5,000
Letter
19950823
Eligible
10/29/2024
11/21/2024
$15,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
4000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1995
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1957
Red Tag Issue Date:
Last Used Date:
7/1/1994
Fee Due:
$0.00
Product Date:
1/1/1957
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1995
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1957
Red Tag Issue Date:
Last Used Date:
7/1/1994
Fee Due:
$0.00
Product Date:
1/1/1957
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1995
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1957
Red Tag Issue Date:
Last Used Date:
7/1/1994
Fee Due:
$0.00
Product Date:
1/1/1957
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1995
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1957
Red Tag Issue Date:
Last Used Date:
7/1/1994
Fee Due:
$0.00
Product Date:
1/1/1957
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1995
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1957
Red Tag Issue Date:
Last Used Date:
7/1/1994
Fee Due:
$0.00
Product Date:
1/1/1957
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
2000
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1995
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1957
Red Tag Issue Date:
Last Used Date:
7/1/1994
Fee Due:
$0.00
Product Date:
1/1/1957
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1995
OSFM
First Notify Date:
5/23/1995
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1957
Red Tag Issue Date:
Last Used Date:
7/1/1994
Fee Due:
$0.00
Product Date:
1/1/1957
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
10000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/6/2023
OSFM
First Notify Date:
5/23/1995
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
5/10/1995
Red Tag Issue Date:
Last Used Date:
10/18/2019
Fee Due:
$0.00
Product Date:
5/15/1995
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
11/1/2019
11/1/2022
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
8/19/2019
8/19/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
8/19/2019
8/19/2020
Overfill Prev Device
Overfill Drop Tube Valve
12/10/2019
12/10/2022
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
12/11/2019
12/11/2022
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank
Fiberglass Single Wall XERXES
Precision Test (Tank)
Pass
1/24/2020
Tank Number 9
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/6/2023
OSFM
First Notify Date:
5/23/1995
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
5/10/1995
Red Tag Issue Date:
Last Used Date:
10/18/2019
Fee Due:
$0.00
Product Date:
5/10/1995
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
11/1/2019
11/1/2022
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
8/19/2019
8/19/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
8/19/2019
8/19/2020
Overfill Prev Device
Overfill Drop Tube Valve
12/10/2019
12/10/2022
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
12/11/2019
12/11/2022
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
12/19/2019
Tank
Fiberglass Single Wall XERXES
Precision Test (Tank)
Fail
1/24/2020
Tank Number 10
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
12/6/2023
OSFM
First Notify Date:
5/23/1995
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
5/10/1995
Red Tag Issue Date:
Last Used Date:
10/18/2019
Fee Due:
$0.00
Product Date:
5/15/1995
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
11/1/2019
11/1/2022
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
7/6/2017
7/6/2018
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
8/19/2019
8/19/2020
Overfill Prev Device
Overfill Drop Tube Valve
12/10/2019
12/10/2022
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
12/11/2019
12/11/2022
Tank
Fiberglass Single Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
8/19/2019
Tank
Fiberglass Single Wall XERXES
Precision Test (Tank)
Fail
1/29/2020
Tank Number 11
Capacity:
550
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
4/21/1995
OSFM
First Notify Date:
1/1/1902
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/1/1973
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 11/12
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 13/14
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found