Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2020424
Status: Active
Facility Name: Ashland Petro
Address: 611 E. Ashland Ave.
Aurora, IL 60505
County: Kane
Property Parcel: 15-34-230-011
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000200
Green Tag Issue Date: 10/21/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Saraf, Inc.
Owner Address: 1911 Midwest Club Parkway
Oak Brook, IL 60523
Owner Status: Current Owner
Purchase Date: 12/2/2003
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/18/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/21/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031124 Saraf, Inc. Current Owner 12/2/2003
U0012348 R. D. Marcley, Inc. Former Owner 10/30/1998
U0009673 Marcley Oil Co Former Owner
U0009673 Marcley Oil Co Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
09-1082 9/30/2009 Removal Log 00429-2009REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-0088 Eligible 4/29/1997 5/29/1997 $10,000
03-0223 Eligible 7/3/2003 7/21/2003 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/30/2009
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/30/2009
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Piping Mechanical Pressurized Line Leak Detection
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/30/2009
OSFM First Notify Date: 5/8/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Piping Stainless Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/19/2009 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 11/12/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2024 7/31/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 7/31/2024 7/31/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/31/2024 7/31/2025
Overfill Prev Device Ball Float Vent Valve 7/31/2024 7/31/2027
Overfill Prev Device Overfill Drop Tube Valve 7/31/2024 7/31/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/31/2024 7/31/2027
Leak Detect - Piping Sump Sensor 7/31/2024 7/31/2025
Spill Contain Device Single Wall Spill Bucket 7/31/2024 7/31/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/31/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/31/2024



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/19/2009 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 11/12/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/31/2024 7/31/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i with CSLD 7/31/2024 7/31/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/31/2024 7/31/2025
Overfill Prev Device Ball Float Vent Valve 7/31/2024 7/31/2027
Overfill Prev Device Overfill Drop Tube Valve 7/31/2024 7/31/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/31/2024 7/31/2027
Leak Detect - Piping Sump Sensor 7/31/2024 7/31/2025
Spill Contain Device Single Wall Spill Bucket 7/31/2024 7/31/2027
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/31/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/31/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/31/2024 7/31/2027
Leak Detect - Piping Sump Sensor 7/31/2024 7/31/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/31/2024 7/31/2027
Leak Detect - Piping Sump Sensor 7/31/2024 7/31/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/31/2024 7/31/2027
Leak Detect - Piping Sump Sensor 7/31/2024 7/31/2025

MFD Motorfuel Dispensing Forms