Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2020419
Status: Inactive
Facility Name: Liberty Citgo, Inc.
Address: 1005 Liberty Street Elgin, IL 60120
County: Kane
Property Parcel: 06-12-237-013
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: N000810
Green Tag Issue Date: 4/18/2012
Green Tag Expire Date: 12/31/2014
MFD Type: N/A

Owner Details

Owner Name: EMA Liberty Corporation
Owner Address: 1005 Liberty Street Elgin, IL 60120
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/23/2013

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036498 EMA Liberty Corporation Current Owner
U0023061 Marvi Kaizar Former Owner 6/15/1994
U0008300 National Oil Company Former Owner 12/31/1967
U0033624 EMA Liberty Corporation Former Owner
U0025917 Marvi Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261672 (Pending)    Issue Date: 6/30/2026    Expiration Date: 8/29/2026    View NOV Form

Tanks Violations
2, 3, 4 Failed to Empty the Tank to 1" or Less - Per 175.810(a)(1) when placing tanks out of service, the tanks and lines must be emptied immediately. The UST is considered empty when all materials have been removed to one inch or less.Upon my reinspection on 3/27/2025, I took stick readings of each tank and found tank 2 had 6" , tank 3 had 8', and tank 4 had 5" of product. Neew red tags were placed on all 3 tanks that date.
Facility Financial responsibility must be reported yearly - Financial Responsibility shall be declared annually, and must be maintained until the tanks are removed or properly abandoned in place by a licensed UST decommissioning contractor. The form can be found at: https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
2, 3, 4 Remove tank(s) - Single-Walled, Over 30 Years Old and OOS Over One Year - These single wall tanks were taken out of service on 3/12/2014 and tanks 2 & 3 are 50 years old and tank 4 is 31 years old. Per 175.810(e) these tanks must be removed as they are condemned. Here is the link to licensed UST Decommissioning contractors that can perform UST tank removals: https://webapps.sfm.illinois.gov/ustsearch/ContractorSearch.aspx
Facility Submit Notification Form for Ownership Change - Per 41 Ill. Adm. Code 176.440(g), a change in ownership information must be reported on an electronic Notification for Underground Storage Tank form, within 30 days of the change. According to Kane County, a Deed was recoded 5/29/2026. The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
94-1963 Eligible 12/6/1994 1/12/1995 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/22/1994
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 3/31/1994 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 50 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date: 3/27/2025
Last Used Date: 3/12/2014 Fee Due: $0.00
Product Date: 1/1/1976

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 4/18/2012 4/18/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/19/2012 4/19/2013
Leak Detect - Tank Automatic Tank Gauging EASI Level-Tru No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 50 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date: 3/27/2025
Last Used Date: 3/12/2014 Fee Due: $0.00
Product Date: 1/1/1976

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 4/18/2012 4/18/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/19/2012 4/19/2013
Leak Detect - Tank Automatic Tank Gauging EASI Level-Tru No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/24/1997 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/10/1995 Red Tag Issue Date: 3/27/2025
Last Used Date: 3/12/2014 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/19/2012 4/19/2013
Leak Detect - Tank Automatic Tank Gauging EASI Level-Tru No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Owens Corning Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found