Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2020325
Status: Active
Facility Name: SRAND Gas Station, LLC
Address: 2601 Grand Avenue
Waukegan, IL 60085
County: Lake
Property Parcel: 08-19-204-004
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00868
Green Tag Issue Date: 4/7/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: SRAND Real Estate, LLC
Owner Address: 2601 Grand Avenue
Waukegan, IL 60085
Owner Status: Current Owner
Purchase Date: 7/30/2024
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/26/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/7/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041306 SRAND Real Estate, LLC Current Owner 7/30/2024
U0023084 Graham Enterprise, Inc. Former Owner 4/28/2009
U0023834 BP Amoco Former Owner 1/1/1988
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/4/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: 8/2/1988 Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/4/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: 8/2/1988 Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/4/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: 8/2/1988 Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/4/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: 8/2/1988 Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/4/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: 8/2/1988 Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/19/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/11/2025 2/11/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/11/2025 2/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/11/2025 2/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R 2/11/2025 2/11/2026
Overfill Prev Device Overfill Drop Tube Valve 2/11/2025 2/11/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/11/2025 2/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 2/11/2025
Tank STIP3 Single Wall Precision Test (Tank) Pass 2/11/2025



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/19/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/11/2025 2/11/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/11/2025 2/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/11/2025 2/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R 2/11/2025 2/11/2026
Overfill Prev Device Overfill Drop Tube Valve 2/11/2025 2/11/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/11/2025 2/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 2/11/2025
Tank STIP3 Single Wall Precision Test (Tank) Pass 2/11/2025



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/19/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 2/11/2025 2/11/2026
Corrosion Prot - Tank Impressed Current Cathodic Protection 2/11/2025 2/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/11/2025 2/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R 2/11/2025 2/11/2026
Overfill Prev Device Overfill Drop Tube Valve 2/11/2025 2/11/2028
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/11/2025 2/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test (Piping) Pass 2/11/2025
Tank STIP3 Single Wall Precision Test (Tank) Pass 2/11/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms