Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2020317
Status: Active
Facility Name: Cyto Three Real Estate, Inc. BP
Address: 2758 North Harlem
Elmwood Park, IL 60635
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001497
Green Tag Issue Date: 7/11/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Cyto Three Real Estate, Inc.
Owner Address: 6834 North Kedvale Rd.
Lincolnwood, IL 60712
Owner Status: Current Owner
Purchase Date: 8/18/2008
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 5/4/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/11/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034941 Cyto Three Real Estate, Inc. Current Owner 8/18/2008
U0023834 BP Amoco Former Owner 4/13/1995
U0027493 Amoco Oil Company Former Owner
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00508-2025CAT Cathodic Protection Approved / Issued 4/29/2025 4/29/2025 10/29/2025 Documents

Notice of Violations (Current)

NOV Number: E0020250863 (Pending)    Issue Date: 4/1/2025    Expiration Date: 5/31/2025    View NOV Form

Tanks Violation
1, 2, 3 Install corrosion protection under dispensers to protect exposed flex connectors and other metal portions of product piping.
Facility Missing copies of current testing certificates for operator training
1, 2 Shear valve(s) not in proper working order.
1, 2, 3 Shear valve(s) not properly mounted and/or not at proper height. - Shear valves are not properly mounted
1, 2, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
88-1148 Eligible 7/30/1999 8/12/1999 $50,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/11/2023 7/11/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/11/2023 7/11/2026
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 7/11/2023 7/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2024 9/25/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/25/2024 9/25/2025
Overfill Prev Device Overfill Drop Tube Valve 9/25/2024 9/25/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/25/2024 9/25/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/3/2019
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/25/2024
Tank STIP3 Single Wall Precision Test (Tank) Pass 3/9/2021



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/11/2023 7/11/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/11/2023 7/11/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 7/11/2023 7/11/2026
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/25/2024 9/25/2025
Overfill Prev Device Overfill Drop Tube Valve 9/25/2024 9/25/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/25/2024 9/25/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/3/2019
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/25/2024



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/11/2023 7/11/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/2/2025 5/2/2028
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/11/2023 7/11/2026
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 7/11/2023 7/11/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2024 9/25/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/25/2024 9/25/2025
Overfill Prev Device Overfill Drop Tube Valve 9/25/2024 9/25/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/25/2024 9/25/2027
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/3/2019
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/25/2024



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/12/2007
OSFM First Notify Date: 11/16/1988 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: 12/11/2007 Fee Due: $0.00
Product Date: 1/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/22/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/22/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/22/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/22/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/22/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms