Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019946
Status: Closed
Facility Name: Williams Service Center
Address: 10 W Streamwood Blvd Streamwood, IL 60107
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: M000509
Green Tag Issue Date: 7/14/2011
Green Tag Expire Date: 12/31/2013
MFD Type: N/A

Owner Details

Owner Name: Williams Service Center
Owner Address: 10 W Streamwood Blvd Streamwood, IL 60107
Owner Status: Current Owner
Purchase Date: 1/28/1986
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/12/2011

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0016448 Williams Service Center Current Owner 1/28/1986

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
12-0839 9/24/2012 Removal Log 00850-2012REM
94-2265 10/6/1994 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
94-2266 Eligible 12/5/1994 1/3/1995 $10,000
12-0839 Eligible 10/11/2012 11/30/2012 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/24/2012
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 12/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/21/2011 1/21/2014
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/27/2010 9/27/2011
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Double Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/24/2012
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 12/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/21/2011 1/21/2014
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/27/2010 9/27/2011
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Double Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/24/2012
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 12/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/21/2011 1/21/2014
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/27/2010 9/27/2011
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Double Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/1994
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 5

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Fuel Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 10/6/1994
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found