Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019889
Status: Active
Facility Name: Kedzie Food & Fuel, Inc.
Address: 3202 W. Cermak Rd.
Chicago, IL 60623
County: Cook
Property Parcel: 16-23-428-037-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002186
Green Tag Issue Date: 11/13/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Cermak & Kedzie Property, LLC
Owner Address: 11399 Brook Hill Drive
Orland Park, IL 60467
Owner Status: Current Owner
Purchase Date: 3/16/2021
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/13/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040585 Cermak & Kedzie Property, LLC Current Owner 3/16/2021
U0032206 PBSS, Inc. Former Owner 7/1/2004
U0007404 Illinois Petroleum Company, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 5/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/3/2023 11/3/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/19/2022 12/19/2023
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/11/2024 10/11/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 10/11/2024 10/11/2025
Overfill Prev Device Overfill Drop Tube Valve 12/19/2022 12/19/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/8/2022 6/8/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 10/11/2024



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 5/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/3/2023 11/3/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/11/2024 10/11/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 10/11/2024 10/11/2025
Overfill Prev Device Overfill Drop Tube Valve 6/8/2022 6/8/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/8/2022 6/8/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 8/5/2020
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 12/30/2021



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 5/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/3/2023 11/3/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/11/2024 10/11/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 10/11/2024 10/11/2025
Overfill Prev Device Overfill Drop Tube Valve 6/8/2022 6/8/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L N/A N/A
Piping Stainless Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 5/16/2022 5/16/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/8/2022 6/8/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 10/11/2024
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test (Piping) Pass 12/19/2022
Piping Stainless Steel Single Wall Piping Precision Test (Piping) Pass 5/16/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found