Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2019245
Status: Active
Facility Name: BP
Address: 29849 E. Lorenzo Rd. Wilmington, IL 60481
County: Will
Property Parcel: 03-17-15-100-007-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001638
Green Tag Issue Date: 11/20/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Elite Midwest Properties, LLC
Owner Address: 1535 W. Grand Avenue Chicago, IL 60642
Owner Status: Current Owner
Purchase Date: 5/31/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/1/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/19/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041350 Elite Midwest Properties, LLC Current Owner 5/31/2017
U0038862 SJK1, Inc. Former Owner 6/1/2017
U0004152 DLM Oil Corporation Former Owner 7/1/1986

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1991
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/27/1987 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/27/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/27/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/19/2024 8/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/19/2024 8/19/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/28/2025 1/28/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/19/2024 8/19/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024



Tank Number 6

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 11/2/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/2/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/19/2024 8/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/19/2024 8/19/2025
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/15/2024 10/15/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/19/2024 8/19/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024



Tank Number 7

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 11/2/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/2/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/19/2024 8/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/19/2024 8/19/2025
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/15/2024 10/15/2025
Spill Contain Device Double Wall Spill Bucket 10/9/2024 10/9/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024



Tank Number 8

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/18/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 11/2/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/2/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/19/2024 8/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/19/2024 8/19/2025
Overfill Prev Device Overfill Drop Tube Valve 8/19/2024 8/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/9/2024 10/9/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/19/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/19/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 10s/11m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 11s/12m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 12s

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 9m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025



Name\ID 9s/10m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2024 8/19/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2024 8/19/2025

MFD Motorfuel Dispensing Forms

No Forms Found