Division of Petroleum & Chemical Safety

 
Pay Tank Fees Online Print Detail Page Export to Excel

Facility Details

Facility Number: 2018874
Status: Active
Facility Name: Circle K #6893
Address: 1001 W. Route 34 Plano, IL 60178
County: Kendall
Property Parcel: 01-28-227-015
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000148
Green Tag Issue Date: 8/13/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: RDK Ventures LLC
Owner Address: 1120 W. Warner Rd. Tempe, AZ 85284
Owner Status: Current Owner
Purchase Date: 11/27/2018
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures LLC Current Owner 11/27/2018
U0038285 Carls Oil Company, Inc. Former Owner
U0004699 Elmer Carls Oil Company, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020260912 (Pending)    Issue Date: 4/7/2026    Expiration Date: 6/6/2026    View NOV Form

Tanks Violations
7 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - T7 Regular STP lid supporting collar is rusted away. Replace supporting collar so lid is secured.
6, 7 Dispensers - hoses cracked, split or worn and require replacement - Replace main hose.
Facility Facility Operation and Maintenance Plan not completed or available. - Update information and leave in Fire Marshal book.
10 Miscellaneous - Double wall spill bucket is not functioning properly.
Facility Missing copy of emergency instructions or emergency procedures plan - Update information and leave in Fire Marshal book.
9, 10 Not Vented Properly - Vents shall be minimium 12' above grade.
6, 7 Shear valve(s) not properly mounted and/or not at proper height. - The shear valve is not secured and is not at the proper height.
6, 7, 9, 10 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - 175.405 a) 1) A) Spill containment equipment that will prevent release of product to the environment when the transfer hose is detached from the fill pipe (e.g., a spill catch basin). Spill containment equipment shall be maintained in a dry, clean state.
7 Stick inserted in drop tube overfill device rendering it inoperative - Remove stick. - There are two sticks in the overfill drop tube valve. Both need to be removed.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
91-1768 Returned 8/22/1995 9/29/1995 $15,000
20250424 Eligible 9/16/2025 9/17/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 8000 Gasoline Removed Federal $0.00 09/19/1988 - REM
2 10000 Gasoline Removed Federal $0.00 06/14/1991 - REM
3 4000 Diesel Fuel Removed Federal $0.00 09/19/1988 - REM
4 4000 Diesel Fuel Removed Federal $0.00 09/19/1988 - REM
5 560 Kerosene Removed Federal $0.00 06/14/1991 - REM
6 10000 Gasoline - Premium Currently in use Federal $0.00
7 10000 Gasoline - Regular Currently in use Federal $0.00
8 10000 Gasoline - Premium Abandoned in place Federal $0.00 06/25/2025 - ABN
9 10000 Diesel Fuel Currently in use Federal $0.00
10 4000 Kerosene Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
3/4 Active
5/6 Active
7/8 Active
9/10 Active
11 Active

MFD Motorfuel Dispensing Forms

No Forms Found