Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2018464
Status: Active
Facility Name: Will County Division of Transportation
Address: 25930 S Egyptian Trail Monee, IL 60449
County: Will
Property Parcel: 12-14-20-400-004-0000
Facility Type: County
Owner Type: County
Green Tag Decal: Z003553
Green Tag Issue Date: 7/5/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Fleet

Owner Details

Owner Name: Will County Division of Transportation
Owner Address: 16841 West Laraway Road Joliet, IL 60433
Owner Status: Current Owner
Purchase Date: 1/1/1988
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 8/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0016414 Will County Division of Transportation Current Owner 1/1/1988

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2025-0209 4/22/2025 Removal Log 00360-2025REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20250209 Eligible 5/23/2025 6/4/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1988
OSFM First Notify Date: 12/16/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1988
OSFM First Notify Date: 12/16/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/22/2025
OSFM First Notify Date: 12/16/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/17/2023 3/17/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/24/2025 3/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/24/2025 3/24/2026
Overfill Prev Device Overfill Alarm 7/5/2024 7/5/2027
Overfill Prev Device Overfill Drop Tube Valve 7/5/2024 7/5/2027
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Flex Connector Steel Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 7/5/2024 7/5/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/24/2025



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/22/2025
OSFM First Notify Date: 12/16/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1988

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/17/2023 3/17/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/24/2025 3/24/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/24/2025 3/24/2026
Overfill Prev Device Overfill Alarm 7/5/2024 7/5/2027
Overfill Prev Device Overfill Drop Tube Valve 7/5/2024 7/5/2027
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Flex Connector Steel Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 7/5/2024 7/5/2027
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 3/24/2025



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/3/2025 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 5/1/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/28/2025

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/3/2026 6/3/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/3/2026 6/3/2027
Overfill Prev Device Overfill Alarm 6/2/2025 6/2/2028
Overfill Prev Device Overfill Drop Tube Valve 6/2/2025 6/2/2028
Piping Flexible Double Wall A.P.T. Poly Tech Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/2/2025 6/2/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/2/2025 6/2/2028
Spill Contain Device Double Wall Spill Bucket 6/2/2025 6/2/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 6/3/2026
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 6/2/2025



Tank Number 6

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/3/2025 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 5/1/2025 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/28/2025

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/3/2026 6/3/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/3/2026 6/3/2027
Overfill Prev Device Overfill Alarm 6/2/2025 6/2/2028
Overfill Prev Device Overfill Drop Tube Valve 6/2/2025 6/2/2028
Piping Flexible Double Wall A.P.T. Poly Tech Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 6/2/2025 6/2/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/2/2025 6/2/2028
Spill Contain Device Double Wall Spill Bucket 6/2/2025 6/2/2028
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 6/3/2026
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 6/2/2025

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2025 6/2/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/3/2026 6/3/2027



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2025 6/2/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/3/2026 6/3/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found