Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2017593
Status: Active
Facility Name: Central Transport, Inc.
Address: 200 North Manheim
Hillside, IL 60164
County: Cook
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z004255
Green Tag Issue Date: 10/16/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Central Transport, Inc.
Owner Address: 12225 Stephens
Warren, MI 48089
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/2/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/16/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0021578 Central Transport, Inc. Current Owner
U0001348 Bellemead Development Corp Former Owner 12/31/1967
U0021944 Crown Enterprises, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00190-2025UPG Upgrade Approved / Issued 2/19/2025 2/20/2025 8/20/2025 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
88-1607 Eligible 6/7/1994 7/12/1994 $50,000
Pay Tank Fees Online

Tank Information



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/30/1989
OSFM First Notify Date: 2/3/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/31/1989
OSFM First Notify Date: 2/3/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1989
OSFM First Notify Date: 2/3/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 2000 Petroleum Use:
Product: Ethylene Glycol CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/24/1989
OSFM First Notify Date: 2/3/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/24/1989
OSFM First Notify Date: 2/3/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/23/1989
OSFM First Notify Date: 2/3/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/23/1989
OSFM First Notify Date: 2/3/1989 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 30000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/21/2003
OSFM First Notify Date: 3/9/1992 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 1/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/21/2003
OSFM First Notify Date: 3/9/1992 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 1/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/31/1989
OSFM First Notify Date: 4/3/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/10/2008 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 6/2/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/3/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/25/2025 4/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 4B 4/25/2025 4/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/25/2025 4/25/2026
Overfill Prev Device Overfill Drop Tube Valve 5/17/2024 5/17/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 10/13/2023 10/13/2026
Leak Detect - Piping Sump Sensor 5/17/2024 5/17/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/25/2025 4/25/2026
Spill Contain Device Single Wall Spill Bucket 10/16/2024 10/16/2027
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 6/24/2022

Dispenser Information



Name\ID 1 M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/13/2023 10/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/25/2025 4/25/2026



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/13/2023 10/13/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/25/2025 4/25/2026

MFD Motorfuel Dispensing Forms