Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2017399
Status: Active
Facility Name: Gulf
Address: 1184 North Convent Street Bourbonnais, IL 60914
County: Kankakee
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000960
Green Tag Issue Date: 4/9/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Shaddy's Convenient Mart, Inc.
Owner Address: 1184 N. Convent Street Bourbonnais, IL 60914
Owner Status: Current Owner
Purchase Date: 8/1/2015
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/28/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/9/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038026 Shaddy's Convenient Mart, Inc. Current Owner 8/1/2015
U0028922 C.F.M.I., Inc. Former Owner 11/1/1999
U0012623 Remote Service, Inc. Former Owner 12/31/1967
U0027520 Remote Services Inc Dba Dairy Mart Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00005-2026UPG Upgrade Approved / Issued 1/2/2026 1/4/2026 7/7/2026 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
96-1159 6/27/1996 Removal Log
99-1483 6/19/1999 Removal Log 02254-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-1159 Eligible 10/1/1996 10/23/1996 $10,000
99-1483 Eligible 10/7/1999 10/12/1999 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance: UNKNOWN
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/19/1999
OSFM First Notify Date: 12/19/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance: UNKNOWN
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/19/1999
OSFM First Notify Date: 12/19/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance: UNKNOWN
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/19/1999
OSFM First Notify Date: 12/19/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/27/1996
OSFM First Notify Date: 12/19/1986 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 12/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 11/1/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/6/2025 2/6/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/6/2025 2/6/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2025 2/21/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 10/2/2023 10/2/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Double Wall Spill Bucket 1/13/2026 1/13/2029
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/6/2025
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 6/11/2021
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 10/5/2023



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/22/1999 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 11/1/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/1/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/6/2025 2/6/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/6/2025 2/6/2026
Overfill Prev Device Overfill Drop Tube Valve 2/21/2025 2/21/2028
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 10/2/2023 10/2/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/14/2023 6/14/2026
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/6/2025
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 6/11/2021
Piping Fiberglass Single Wall Piping Ameron Precision Test (Piping) Pass 10/5/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2023 10/2/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/2/2023 10/2/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found