Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2017072
Status: Active
Facility Name: Lutheran General Hospital
Address: 1775 West Dempster
Park Ridge, IL 60068
County: Cook
Property Parcel:
Facility Type: Hospital
Owner Type: Private
Green Tag Decal: Y002027
Green Tag Issue Date: 12/8/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Lutheran General Hospital
Owner Address: 1775 West Dempster
Park Ridge, IL 60068
Owner Status: Current Owner
Purchase Date: 12/1/1958
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/4/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 12/8/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009443 Lutheran General Hospital Current Owner 12/1/1958

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-1027 9/5/2014 Removal Log 00478-2014REM
99-1845 8/4/1999 Removal Log 02227-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-1845 Eligible 12/5/2000 12/20/2000 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 4/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 11/20/2024 11/20/2025
Overfill Prev Device Overfill Drop Tube Valve 7/15/2024 7/15/2027
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 11/3/2021 11/3/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/15/2024 7/15/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 11/20/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/20/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 5/21/2008



Tank Number 2

Capacity: 2000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 4/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/18/2024 11/18/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 11/20/2024 11/20/2025
Overfill Prev Device Overfill Drop Tube Valve 7/15/2024 7/15/2027
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/15/2024 7/15/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 11/20/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/20/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 5/21/2008



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: 50 Abandoned Date:
Install Date: 4/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/22/2024 11/22/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 11/22/2024 11/22/2025
Overfill Prev Device Overfill Drop Tube Valve 10/10/2024 10/10/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 11/17/2021 11/17/2022
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 10/10/2024 10/10/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 4/22/2022
Tank Fiberglass Single Wall Precision Test (Tank) Pass 11/22/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 5/21/2008



Tank Number 4

Capacity: 2500 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/5/2014
OSFM First Notify Date: 1/22/1992 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 8/1/1991 Red Tag Issue Date:
Last Used Date: 9/1/2014 Fee Due: $0.00
Product Date: 8/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Piping Sump Sensor 7/25/2013 7/25/2014
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel iTouch
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 7/25/2013 7/25/2014
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 11/16/2010



Tank Number 5

Capacity: 20000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 8/4/1999
OSFM First Notify Date: 2/16/1993 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 12/1/1958 Red Tag Issue Date:
Last Used Date: 7/1/1999 Fee Due: $0.00
Product Date: 12/1/1958

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 20000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 8/4/1999
OSFM First Notify Date: 2/16/1993 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 12/1/1958 Red Tag Issue Date:
Last Used Date: 7/1/1999 Fee Due: $0.00
Product Date: 12/1/1958

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/13/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 8/12/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/12/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 11/18/2024 11/18/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 11/27/2024 11/27/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/20/2024 11/20/2025
Overfill Prev Device Overfill Drop Tube Valve 7/15/2024 7/15/2027
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Double Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/15/2024 7/15/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 11/20/2024
Tank Fiberglass Double Wall Precision Test (Tank) Pass 11/20/2024
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 5/21/2008

Dispenser Information



Name\ID REG

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found