Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2016782
Status: Active
Facility Name: 7-Eleven Store #38743
Address: 14 N. Elmhurst Road
Wheeling, IL 60090
County: Cook
Property Parcel: 03-03-307-032-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X003217
Green Tag Issue Date: 8/4/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: 14 N Elmhurst, LLC
Owner Address: 880 N. Addison Avenue
Elmhurst, IL 60126
Owner Status: Current Owner
Purchase Date: 5/28/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/7/2020 12/31/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039576 14 N Elmhurst, LLC Current Owner 5/28/2019
U0036468 Bharuch, LLC Former Owner 8/23/2011
U0031954 Gas Mart USA, Inc. Former Owner 2/12/2004
U0032024 Chicago Petromarts, Inc. Former Owner 1/1/2004
U0031087 Conoco Phillips Former Owner 1/1/2003
U0026005 Phillips 66 Petroleum Co Former Owner 1/1/1986
U0011868 Phillips 66 Company Former Owner 12/31/1967
U0029689 Parkway Bank Former Owner
U0011862 Phillips Petroleum Co Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
19-0886 8/26/2019 Removal Log 01291-2019REM
19-0886 8/27/2019 Removal Log 01291-2019REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
03-1594 Eligible 4/1/2004 4/21/2004 $10,000
20190886 Eligible 2/18/2020 2/25/2020 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/27/2019
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 5/28/2019 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/10/2018 1/10/2021
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/10/2018 1/10/2019
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve 7/26/2018 7/26/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/26/2018 7/26/2021
Tank Composite Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/27/2019
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 5/28/2019 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/10/2018 1/10/2021
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/10/2018 1/10/2019
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve 7/26/2018 7/26/2021
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/26/2018 7/26/2021
Tank Composite Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/27/2019
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 5/28/2019 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/10/2018 1/10/2021
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/10/2018 1/10/2019
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve 7/26/2018 7/26/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/26/2018 7/26/2021
Tank Composite Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/26/2019
OSFM First Notify Date: 2/6/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: 5/28/2019 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/10/2018 1/10/2021
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/10/2018 1/10/2019
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve 7/26/2018 7/26/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/26/2018 7/26/2021
Tank Composite Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 5/7/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/20/2023 7/20/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/20/2023 7/20/2024
Overfill Prev Device Overfill Drop Tube Valve 7/20/2023 7/20/2026
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 8/16/2023 8/16/2026
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 10/9/2020 10/9/2021
Leak Detect - Piping Sump Sensor with positive shutdown 7/20/2023 7/20/2024
Spill Contain Device Double Wall Spill Bucket 7/20/2023 7/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test Pass 10/9/2020
Piping Polyethylene Chase Precision Test Pass 10/9/2020
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/9/2020



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 5/7/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/20/2023 7/20/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/20/2023 7/20/2024
Overfill Prev Device Overfill Drop Tube Valve 7/20/2023 7/20/2026
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 8/16/2023 8/16/2026
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 10/9/2020 10/9/2021
Leak Detect - Piping Sump Sensor with positive shutdown 7/20/2023 7/20/2024
Spill Contain Device Double Wall Spill Bucket 7/20/2023 7/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test Pass 10/9/2020
Piping Polyethylene Chase Precision Test Pass 10/9/2020
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/9/2020



Tank Number 7

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 5/7/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/20/2023 7/20/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/20/2023 7/20/2024
Overfill Prev Device Overfill Drop Tube Valve 7/20/2023 7/20/2026
Piping Polyethylene Chase N/A N/A
Piping Flexible Double Wall OPW Flexworks N/A N/A
Piping Single Wall STP/Tanktop Sump 8/16/2023 8/16/2026
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 10/9/2020 10/9/2021
Leak Detect - Piping Sump Sensor with positive shutdown 7/20/2023 7/20/2024
Spill Contain Device Double Wall Spill Bucket 7/20/2023 7/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test Pass 10/9/2020
Piping Polyethylene Chase Precision Test Pass 10/9/2020
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/9/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2023 8/16/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/20/2023 7/20/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2023 8/16/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/20/2023 7/20/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2023 8/16/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/20/2023 7/20/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2023 8/16/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/20/2023 7/20/2024

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2016782 7-Eleven Store #38743 Wheeling 04/16/2020 Letter Form