Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0037337 |
Lehigh Gas Wholesale Services Inc. |
Current Owner |
9/27/2016 |
| U0000651 |
B.A.P.A., LLC & PT, LLC |
Former Owner |
12/3/1999 |
| U0025164 |
BAPA, LLC & PT, LLC |
Former Owner |
|
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 2021-0851 |
10/7/2021 |
Removal Log |
01100-2021REM |
| 2021-0851 |
10/21/2021 |
Removal Log |
01100-2021REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 20181123 |
Eligible |
1/21/2019
|
1/24/2019
|
$5,000
|
Letter
|
Tank Number 1
| Capacity: |
7500 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
12/1/1988 |
|
OSFM
First Notify Date: |
1/28/1986 |
|
Abandoned Material: |
|
| Current Age: |
32 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
7500 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
12/1/1988 |
|
OSFM
First Notify Date: |
1/28/1986 |
|
Abandoned Material: |
|
| Current Age: |
32 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
None |
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/7/2021 |
|
OSFM
First Notify Date: |
12/19/1988 |
|
Abandoned Material: |
|
| Current Age: |
32 |
|
Abandoned Date: |
|
| Install Date: |
12/1/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
11/30/2018 |
|
Fee Due: |
$0.00 |
| Product Date: |
12/1/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
2/19/2018 |
2/19/2019 |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
11/29/2018 |
11/29/2019 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
11/29/2018 |
11/29/2019 |
|
Overfill Prev Device
|
Overfill Alarm |
11/29/2018 |
11/29/2021 |
|
Piping
|
Galvanized Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/28/2018 |
11/28/2021 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
12000 |
|
Petroleum Use: |
None |
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/21/2021 |
|
OSFM
First Notify Date: |
12/19/1988 |
|
Abandoned Material: |
|
| Current Age: |
32 |
|
Abandoned Date: |
|
| Install Date: |
12/1/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
11/30/2018 |
|
Fee Due: |
$0.00 |
| Product Date: |
12/1/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
2/19/2018 |
2/19/2019 |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
11/29/2018 |
11/29/2019 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
11/29/2018 |
11/29/2019 |
|
Overfill Prev Device
|
Overfill Alarm |
11/29/2018 |
11/29/2021 |
|
Piping
|
Galvanized Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/28/2018 |
11/28/2021 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
12000 |
|
Petroleum Use: |
None |
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
10/21/2021 |
|
OSFM
First Notify Date: |
12/19/1988 |
|
Abandoned Material: |
|
| Current Age: |
32 |
|
Abandoned Date: |
|
| Install Date: |
12/1/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
11/30/2018 |
|
Fee Due: |
$0.00 |
| Product Date: |
12/1/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
2/19/2018 |
2/19/2019 |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
11/29/2018 |
11/29/2019 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
11/29/2018 |
11/29/2019 |
|
Overfill Prev Device
|
Overfill Alarm |
11/29/2018 |
11/29/2021 |
|
Piping
|
Galvanized Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
11/28/2018 |
11/28/2021 |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found