Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2015079
Status: Inactive
Facility Name: Clake Gas Station, LLC
Address: 451 Virginia Street Crystal Lake, IL 60014
County: McHenry
Property Parcel: 19-06-280-012
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001446
Green Tag Issue Date: 5/14/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Clake Real Estate, LLC
Owner Address: 451 Virginia Street Crystal Lake, IL 60014
Owner Status: Current Owner
Purchase Date: 2/20/2025
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/20/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/14/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041463 Clake Real Estate, LLC Current Owner 2/20/2025
U0039925 Omni Petroleum, Inc. Former Owner 6/23/2019
U0038343 Abdul Hamid Patel Former Owner 1/1/2015
U0033800 Singh, Sawaran Former Owner 8/1/2006
U0001775 Boncosky Oil Company Former Owner 9/20/1994
U0009491 M&R Trust Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252067 (Pending)    Issue Date: 8/13/2025    Expiration Date: 10/12/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain 2 years on site with other annual testing documentation.
4, 6, 7, 8 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (ATG) not completed. Testing shall be completed and submitted to OSFM.
6, 7, 8 Annual line precision and mechanical line leak detector functional test not completed.
4 Annual tank impressed current system test not completed.
Facility Facility Operation and Maintenance Plan not completed or available. - Adopt and implement a written operations and maintenance plan, signed by both the owner and either a Class A or Class B Operator designated for the UST facility An Operations & Maintenance template is available at www.sfm.illinois.gov to download and complete O & M template and maintain completed form on site.
4, 6, 7, 8 Flex connector sacrificial anode system not tested (required every 3 years) - Test anodes and replace as needed - Three-year third-party testing required on sacrificial anode/cathodic protection system. Perform testing and maintain passing documentation on site for review by OSFM Inspector.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and 2 years of documentation maintained on site. 30-Day Walkthrough Inspection form available at www.sfm.illinois.gov. The form must be filled out by an A/B Operator, you must, initial each box that applies, date the form each month to ensure it is being done every 30 days, and the A/B operator must print and sign their name at the bottom. If more than one A/B operator fills out the form, then each must print and sign name at the bottom.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and 2 years documentation maintained on site.
Facility Missing copy of emergency instructions or emergency procedures plan - Emergency Procedures plan shall be maintained on site for viewing and reference as necessary (See Operator Training Rules 176.645). The emergency plan template is available on the OSFM website.
4, 6, 7, 8 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Triennial inspection of overfill device (drop tube valve and overfill alarm) has not been completed. Testing shall be completed with passing results and uploaded to OSFM website.
4, 6, 7, 8 Required monthly tank leak test records not available. - Maintain one PASSing report per TANK, per month, from ATG. Must maintain 24 months’ worth.
6, 7, 8 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Provide documentation that annual testing of all shear valves has been conducted and passed. Must maintain 2 years of inspection reports.
4, 6, 7, 8 Submit Notification Form For Tank Status Change - Submit OSFM Notification Form For Tank Status Change, the Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This is required to place the tanks back into service.
4, 6, 7, 8 Tank monitor does not appear to function properly and requires maintenance. - All Indicator lights on panel of Veeder-Root ATG are not functional. Replace as necessary to provide proper operation.
4, 6, 7, 8 Triennial spill prevention equipment testing not completed. - Triennial inspection/testing of spill bucket(s) has not been completed. Testing shall be completed with passing results uploaded to OSFM.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-0950 Eligible 9/9/1997 9/22/1997 $15,000
97-0950 Ineligible 3/3/2009 3/26/2009 $Not Selected
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1988
OSFM First Notify Date: 3/20/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1988
OSFM First Notify Date: 3/20/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1974

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1988
OSFM First Notify Date: 3/20/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 1/1/1974

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/20/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: 12/16/2024 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 12/5/2023 12/5/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 12/5/2023 12/5/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/5/2023 12/5/2024
Overfill Prev Device Overfill Alarm 12/30/2021 12/30/2024
Overfill Prev Device Overfill Drop Tube Valve 3/10/2022 3/10/2025
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/10/2022 3/10/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 8/15/2022



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Racing Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/20/1986 Abandoned Material:
Current Age: 51 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 12/16/2024 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 12/5/2023 12/5/2024
Corrosion Prot - Tank Impressed Current Cathodic Protection 12/5/2023 12/5/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/5/2023 12/5/2024
Overfill Prev Device Overfill Alarm 12/30/2021 12/30/2024
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/9/2022 8/9/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 8/15/2022



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/1994 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 7/26/1988 Red Tag Issue Date:
Last Used Date: 12/16/2024 Fee Due: $0.00
Product Date: 7/26/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/4/2022 8/4/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/4/2022 8/4/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/4/2022 8/4/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/6/2024 9/6/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/5/2023 12/5/2024
Overfill Prev Device Overfill Alarm 12/30/2021 12/30/2024
Overfill Prev Device Overfill Drop Tube Valve 12/30/2021 12/30/2024
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/4/2022 5/4/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 9/6/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/15/2022



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/1994 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 7/26/1988 Red Tag Issue Date:
Last Used Date: 12/16/2024 Fee Due: $0.00
Product Date: 7/26/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/4/2022 8/4/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/4/2022 8/4/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/5/2023 12/5/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/5/2023 12/5/2024
Overfill Prev Device Overfill Alarm 12/30/2021 12/30/2024
Overfill Prev Device Overfill Drop Tube Valve 12/30/2021 12/30/2024
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/9/2022 8/9/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 4/15/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/15/2022



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/17/1994 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 7/26/1988 Red Tag Issue Date:
Last Used Date: 12/16/2024 Fee Due: $0.00
Product Date: 7/26/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/4/2022 8/4/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/4/2022 8/4/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/5/2023 12/5/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/5/2023 12/5/2024
Overfill Prev Device Overfill Alarm 12/30/2021 12/30/2024
Overfill Prev Device Overfill Drop Tube Valve 3/10/2022 3/10/2025
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/9/2022 8/9/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 12/5/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/15/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found