Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2014726
Status:
Closed
Facility Name:
Circle K #6714
Address:
12810 143rd Street
Homer Glen, IL 60441
County:
Will
Property Parcel:
16-05-02-400-009
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
U002634
Green Tag Issue Date:
11/14/2019
Green Tag Expiration Date:
8/16/2021
Owner Details
Owner Name:
County of Will
Owner Address:
302 N. Chicago Street
Joliet, IL 60435
Owner Status:
Current Owner
Purchase Date:
3/5/2021
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
7/15/2022
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
1/21/2021
12/31/2023
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0016415
County of Will
Current Owner
3/5/2021
U0035671
RDK Ventures, LLC
Former Owner
1/15/2010
U0013849
Shell Oil Products
Former Owner
8/28/1998
U0027449
Equilon Enterprises, LLC
Former Owner
8/15/1993
U0005658
Gas City, Ltd.
Former Owner
12/31/1967
U0031151
Shell Oil Products US c/o Gilbarco Veeder-Root
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2021-0394
8/4/2021
Removal Log
00801-2021REM
21-0394
8/3/2021
Removal Log
00801-2021REM
89-1780
9/23/1993
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
03-0367
Eligible
5/20/2003
6/23/2003
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/22/1993
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
1/1/1986
Red Tag Issue Date:
Last Used Date:
9/20/1993
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/22/1993
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
1/1/1986
Red Tag Issue Date:
Last Used Date:
9/20/1993
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
12000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/22/1993
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
1/1/1986
Red Tag Issue Date:
Last Used Date:
9/20/1993
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
12000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/22/1993
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
1/1/1986
Red Tag Issue Date:
Last Used Date:
9/20/1993
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
2000
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/22/1993
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
1/1/1986
Red Tag Issue Date:
Last Used Date:
4/25/1989
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
2000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/22/1993
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
7
Abandoned Date:
Install Date:
1/1/1986
Red Tag Issue Date:
Last Used Date:
4/25/1989
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
10846
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/3/2021
OSFM
First Notify Date:
11/9/1993
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
9/29/1993
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/29/1993
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
5/28/2020
5/28/2021
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
5/28/2020
5/28/2021
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
5/28/2020
5/28/2021
Overfill Prev Device
Overfill Drop Tube Valve
7/2/2018
7/2/2021
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/12/2018
4/12/2021
Leak Detect - Piping
Sump Sensor
5/28/2020
5/28/2021
Spill Contain Device
Single Wall Spill Bucket
7/2/2018
7/2/2021
Tank
Fiberglass Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
5/28/2020
Tank Number 8
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/4/2021
OSFM
First Notify Date:
11/9/1993
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
9/29/1993
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/29/1993
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Other Non-vented check valve
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
5/28/2020
5/28/2021
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
5/28/2020
5/28/2021
Overfill Prev Device
Overfill Drop Tube Valve
7/2/2018
7/2/2021
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/12/2018
4/12/2021
Leak Detect - Piping
Sump Sensor
5/28/2020
5/28/2021
Spill Contain Device
Single Wall Spill Bucket
7/2/2018
7/2/2021
Tank
Fiberglass Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
5/28/2020
Tank Number 9
Capacity:
12000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/4/2021
OSFM
First Notify Date:
11/9/1993
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
9/29/1993
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/29/1993
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
5/28/2020
5/28/2021
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
5/28/2020
5/28/2021
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
5/28/2020
5/28/2021
Overfill Prev Device
Overfill Drop Tube Valve
7/2/2018
7/2/2021
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/12/2018
4/12/2021
Leak Detect - Piping
Sump Sensor
5/28/2020
5/28/2021
Spill Contain Device
Single Wall Spill Bucket
7/2/2018
7/2/2021
Tank
Fiberglass Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
5/28/2020
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/12/2018
4/12/2021
Leak Detect - Piping
Sump Sensor
5/28/2020
5/28/2021
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/12/2018
4/12/2021
Leak Detect - Piping
Sump Sensor
5/28/2020
5/28/2021
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/12/2018
4/12/2021
Leak Detect - Piping
Sump Sensor
5/28/2020
5/28/2021
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
4/12/2018
4/12/2021
Leak Detect - Piping
Sump Sensor
5/28/2020
5/28/2021
MFD
Motorfuel Dispensing Forms
No Forms Found