Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2014603
Status:
Active
Facility Name:
Speedway Unit 7760
Address:
16649 S Kedzie Ave Markham, IL 60426
County:
Cook
Property Parcel:
28-24-308-014-0000
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA00350
Green Tag Issue Date:
9/19/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Speedway, LLC
Owner Address:
P.O. Box 1500 Springfield, OH 45501
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
12/8/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
9/19/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0026552
Speedway, LLC
Current Owner
U0002795
Emro Marketing Co
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
01676-2025UPG
Upgrade
Approved / Issued
12/19/2025
12/20/2025
6/23/2026
Documents
01642-2025UPG
Upgrade
Approved / Issued
12/9/2025
12/9/2025
6/9/2026
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
90-0219
10/21/1991
Removal Log
92-0219
10/21/1991
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
94-1473
Eligible
8/30/2001
9/25/2001
$10,000
89-0484
Eligible
8/30/2001
9/25/2001
$50,000
90-0219
Eligible
8/30/2001
9/25/2001
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 6
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/21/1992
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/14/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
10/21/2024
10/21/2027
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
9/23/2025
9/23/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
9/23/2025
9/23/2026
Overfill Prev Device
Overfill Drop Tube Valve
12/18/2025
12/18/2028
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Double Wall Spill Bucket
12/18/2025
12/18/2028
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Mid-grade
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/21/1992
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/14/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
10/21/2024
10/21/2027
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
9/23/2025
9/23/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
9/23/2025
9/23/2026
Overfill Prev Device
Overfill Drop Tube Valve
12/18/2025
12/18/2028
Overfill Prev Device
Overfill Drop Tube Valve
12/18/2025
12/18/2028
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
5/14/2024
5/14/2027
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/21/1992
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
11/14/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
10/21/2024
10/21/2027
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
9/23/2025
9/23/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD
9/23/2025
9/23/2026
Overfill Prev Device
Overfill Drop Tube Valve
12/18/2025
12/18/2028
Overfill Prev Device
Overfill Drop Tube Valve
12/18/2025
12/18/2028
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
5/14/2024
5/14/2027
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
4000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/22/1991
OSFM
First Notify Date:
4/18/1986
Abandoned Material:
Current Age:
33
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/22/1991
OSFM
First Notify Date:
4/18/1986
Abandoned Material:
Current Age:
33
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 11
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/22/1991
OSFM
First Notify Date:
4/18/1986
Abandoned Material:
Current Age:
33
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 12
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/22/1991
OSFM
First Notify Date:
4/18/1986
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 13
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/22/1991
OSFM
First Notify Date:
4/18/1986
Abandoned Material:
Current Age:
29
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/1991
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found