Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
2014581
Status:
Closed
Facility Name:
Speedway #7563
Address:
1024 E Glenwood Dyer Road
Glenwood, IL 604252142
County:
Cook
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
M001374
Green Tag Issue Date:
9/12/2011
Green Tag Expiration Date:
12/31/2013
Owner Details
Owner Name:
Speedway, LLC
Owner Address:
P.O. Box 1500
Springfield, OH 45501
Owner Status:
Current Owner
Purchase Date:
1/1/1901
Type of Financial Responsibility:
Surety Bond
Financial Responsibility Reporting Due Date:
1/11/2013
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
9/12/2011
12/31/2013
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0026552
Speedway, LLC
Current Owner
1/1/1901
U0016241
Emro Marketing Company
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
12-1055
10/10/2012
Removal Log
00926-2012REM
12-1055
10/9/2012
Removal Log
00926-2012REM
92-1156
9/25/1992
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
92-1156
Eligible
1/20/1997
2/19/1997
$10,000
12-1055
Eligible
4/30/2013
6/19/2013
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/2012
OSFM
First Notify Date:
1/22/1993
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
9/1/1992
Red Tag Issue Date:
Last Used Date:
10/17/2011
Fee Due:
$0.00
Product Date:
9/1/1992
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
11/14/2010
11/14/2013
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
12/27/2010
12/27/2011
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/2012
OSFM
First Notify Date:
1/22/1993
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
9/1/1992
Red Tag Issue Date:
Last Used Date:
10/17/2011
Fee Due:
$0.00
Product Date:
9/1/1992
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
11/14/2010
11/14/2013
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
12/27/2010
12/27/2011
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/2012
OSFM
First Notify Date:
1/22/1993
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
9/1/1992
Red Tag Issue Date:
Last Used Date:
10/17/2011
Fee Due:
$0.00
Product Date:
9/1/1992
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
11/14/2010
11/14/2013
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
12/27/2010
12/27/2011
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/2012
OSFM
First Notify Date:
1/22/1993
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
9/1/1992
Red Tag Issue Date:
Last Used Date:
10/17/2011
Fee Due:
$0.00
Product Date:
9/1/1992
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
11/14/2010
11/14/2013
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
4000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/25/1992
OSFM
First Notify Date:
3/13/1987
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
9/1/1992
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/25/1992
OSFM
First Notify Date:
3/13/1987
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
9/1/1992
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/10/2012
OSFM
First Notify Date:
3/13/1987
Abandoned Material:
Inert material mixed with portland cement
Current Age:
27
Abandoned Date:
9/1/1992
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/10/2012
OSFM
First Notify Date:
3/13/1987
Abandoned Material:
Inert material mixed with portland cement
Current Age:
27
Abandoned Date:
9/1/1992
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/10/2012
OSFM
First Notify Date:
3/13/1987
Abandoned Material:
Inert material mixed with portland cement
Current Age:
27
Abandoned Date:
9/1/1992
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
550
Petroleum Use:
Product:
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
3/1/1987
OSFM
First Notify Date:
4/18/1986
Abandoned Material:
Current Age:
28
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
1/1/1974
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found