Division of Petroleum & Chemical Safety

 
Pay Tank Fees Online Print Detail Page Export to Excel Last Search Page

Facility Details

Facility Number: 2014561
Status: Active
Facility Name: Speedway #7427
Address: 7201 West 183rd Street
Tinley Park, IL 60477
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003067
Green Tag Issue Date: 10/20/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500
Springfield, OH 45501
Owner Status: Current Owner
Purchase Date: 1/1/1980
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/20/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner 1/1/1980
U0002795 Emro Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020250523 (Pending)    Issue Date: 2/28/2025    Expiration Date: 4/29/2025    View NOV Form

Tanks Violation
12 Install or replace lockable fill pipe caps. - E-85 snap cap is missing the gasket. Repair/replace.
Facility Miscellaneous - (Emergency stop is Blocked inside) Emergency stop shall be readily accessible to the attendant.
2, 3, 4 Piping interstitial must be open in all sumps - Siphon bar double piping is in a closed position.
1, 2, 3, 4, 5, 12 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
2, 3, 4 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - Needs to be tested due to regulated sensors and upgrade in 2014. (All Regular STP tanks top sumps)
2, 3, 4 Verify and test piping sump sensor for positive shutdown - Need to test STP sump sensor in all regular STPs due to siphon bars and Dispensers 1/2 and 11/12. Need to be positve shut down due to upgrade 2014.

NOV Number: E0020250524 (Pending)    Issue Date: 2/28/2025    Expiration Date: 4/29/2025    View NOV Form

Tanks Violation
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers. Reference 175.210 h)

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
92-0930 6/15/1992 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-0930 Eligible 6/10/1996 7/2/1996 $10,000
10-1164 Eligible 12/1/2010 1/10/2011 $5,000
14-1114 Eligible 1/16/2015 2/27/2015 $5,000
14-1080 Eligible 1/16/2015 2/27/2015 $5,000
Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 10000 Gasoline - Premium Currently in use Federal $0.00
2 10000 Gasoline - Regular Currently in use Federal $0.00
3 10000 Gasoline - Regular Currently in use Federal $0.00
4 10000 Gasoline - Regular Currently in use Federal $0.00
5 10000 B-11 Currently in use Federal $0.00
6 4000 Kerosene Removed Federal $0.00 12/02/2014 - REM
7 6000 Diesel Fuel Removed Federal $0.00 06/15/1992 - REM
8 8000 Gasoline Removed Federal $0.00 06/15/1992 - REM
9 8000 Gasoline Removed Federal $0.00 06/15/1992 - REM
10 10000 Gasoline Removed Federal $0.00 06/15/1992 - REM
11 10000 Gasoline Removed Federal $0.00 06/15/1992 - REM
12 6000 E85 Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
3/4 Active
5/6 Active
7/8 Active
9/10 Active
11/12 Active
13/14 Active
15/16 Active

MFD Motorfuel Dispensing Forms

No Forms Found