Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2014268
Status: Active
Facility Name: Barrington Transportation Company, Inc.
Address: 315 S. Hager Avenue Barrington, IL 60010
County: Lake
Property Parcel:
Facility Type: School/College
Owner Type: Private
Green Tag Decal: BB03947
Green Tag Issue Date: 7/13/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Fleet

Owner Details

Owner Name: Barrington Transportation Company, Inc.
Owner Address: 315 S. Hager Avenue Barrington, IL 60010
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 3/12/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0001177 Barrington Transportation Company, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-0309 Returned 11/2/1999 11/16/1999 $Not Selected
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 4/22/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/11/2025 4/11/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 6/20/2023 6/20/2028
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Omntec OEL 8000 II 3/26/2026 3/26/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2026 3/26/2029
Piping Fiberglass Single Wall Piping Ameron Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/11/2025 4/11/2028
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 6/21/2023



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/22/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 4/22/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector Not applicable Not applicable
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/26/2026 3/26/2029
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 6/20/2023 6/20/2028
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Omntec OEL 8000 II 3/26/2026 3/26/2027
Overfill Prev Device Overfill Drop Tube Valve 3/26/2026 3/26/2029
Piping Fiberglass Single Wall Piping Ameron Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/11/2025 4/11/2028
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Steel Single Wall Precision Test (Tank) Pass 6/21/2023

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found