Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2013990
Status: Active
Facility Name: Lansing Municipal Airport
Address: 3250 Bob Malkas Drive
Lansing, IL 60438
County: Cook
Property Parcel:
Facility Type: Airport
Owner Type: Municipal
Green Tag Decal: AA03493
Green Tag Issue Date: 5/15/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Village of Lansing
Owner Address: 3141 Ridge Road
Lansing, IL 60438
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 10/9/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 5/15/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0008906 Village of Lansing Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Jet A CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 10/5/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Annual Prec Line Testing Suction 1/16/2025 1/16/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4i with CSLD 1/16/2025 1/16/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 1/16/2025 1/16/2026
Overfill Prev Device Overfill Drop Tube Valve 1/16/2025 1/16/2028
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/14/2022



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 10/5/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Annual Prec Line Testing Suction 1/16/2025 1/16/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4i with CSLD 1/16/2025 1/16/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 1/16/2025 1/16/2026
Overfill Prev Device Overfill Drop Tube Valve 1/16/2025 1/16/2028
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/16/2025



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Aviation Gas CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 10/5/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4i with CSLD 1/16/2025 1/16/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 1/16/2025 1/16/2026
Overfill Prev Device Overfill Drop Tube Valve 1/16/2025 1/16/2028
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 1/16/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID Av Gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID Jet A

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found