Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2013836
Status: Active
Facility Name: Eknoor, Inc. - Marathon
Address: 1260 East Lake Street Hanover Park, IL 60133
County: Du Page
Property Parcel: 02-06-402-012
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000134
Green Tag Issue Date: 7/23/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: 1260 Lake St LLC
Owner Address: 1080 Nerge Rd., Suite 200 Elk Grove Village, IL 60007
Owner Status: Current Owner
Purchase Date: 1/27/2021
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/1/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040894 1260 Lake St LLC Current Owner 1/27/2021
U0026531 DO NOT USE THIS OWNER ID - Casey's General Stores Former Owner 1/1/1986
U0036711 Hanover Park Enterprises, Inc. Former Owner / Operator 3/1/2012
U0035252 MPCO Real Estate, LLC Former Owner / Operator 1/23/2009
U0009659 Marathon Petroleum Company LP Former Owner / Operator 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020261701 (Pending)    Issue Date: 7/2/2026    Expiration Date: 8/31/2026    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - 175.210 h)The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom.

NOV Number: E0020261728 (Pending)    Issue Date: 7/2/2026    Expiration Date: 8/31/2026    View NOV Form

Tanks Violations
1, 2, 3, 4 Annual electronic line leak detector test not completed. - Line leak detectors need annual testing. Testing shall be performed and passing results entered on OSFM portal.
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shut off switch needs annual testing performed. OSFM form shall be kept on site.
1, 2, 3, 4 Annual leak detection certification not completed (Required annually). - Annual leak detection testing shall be performed and passing results entered on OSFM portal.
1, 2, 3 Dispensers - hoses cracked, split or worn and require replacement - Replace main hoses.
1, 2, 3, 4 Document that emergency shut-off (shear valves) are in proper working order - Shear valves need annual testing performed. OSFM form shall be completed and kept on site.
Facility Facility Operation and Maintenance Plan not completed or available. - Annual, and some triannual testing has not been performed. Print out and complete Operations and Maintenance Plan. Review rules and regulations set forth by OSFM.
Facility Financial responsibility must be reported yearly - Form showing proof of Guaranteed needs to be on site so STSS can review it.
1, 2 Miscellaneous - West observation well lid support is broken and missing.
3 Miscellaneous - ATG has been in alarm for 6 months. Q3 Line Equipment Fault Alarm.
3 Miscellaneous - ATG shows T4 Premium 4 Gallons .94" of water.
3, 4 Miscellaneous - West observation well lid support is broken and missing.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual walkthrough needs to be performed. OSFM form shall be completed and kept on site.
1, 2, 3, 4 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Section 175.405 Spill Containment and Overfill Prevention Equipment c) Overfill prevention equipment must be inspected at installation, immediately after any repairs, and at least once every three years.
3 Precision line test required. - Required due to Q3 alarm for 6 months.
1, 2, 3, 4 Shear valve(s) not properly mounted and/or not at proper height. - Shear valve is not secure. Mounting bracket is missing one side. Repair or replace.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
97-2329 12/8/1997 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
97-2329 Eligible 11/24/1998 1/11/1999 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/28/2025 2/28/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/28/2025 2/28/2026
Leak Detect - Piping Siphon Bar Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/28/2025 2/28/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 5/8/2023 5/8/2026
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 2/28/2025 2/28/2028
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 12/19/2019
Tank Fiberglass Single Wall Precision Test (Tank) Pass 1/17/2020



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Siphon Bar Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/28/2025 2/28/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 5/8/2023 5/8/2026
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 2/28/2025 2/28/2028
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 1/17/2020



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/28/2025 2/28/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/10/2026 7/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/28/2025 2/28/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 5/8/2023 5/8/2026
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 2/28/2025 2/28/2028
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 12/19/2019



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 53 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/28/2025 2/28/2028
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/28/2025 2/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/28/2025 2/28/2026
Overfill Prev Device Ball Only Removed Ball Float Vent Valve Not applicable Not applicable
Overfill Prev Device Overfill Drop Tube Valve 5/8/2023 5/8/2026
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 2/28/2025 2/28/2028
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 12/19/2019



Tank Number 5

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/1997
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1973 Red Tag Issue Date:
Last Used Date: 12/8/1997 Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found