Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2013826
Status: Active
Facility Name: Joliet Marathon
Address: 324 South Larkin Ave. Joliet, IL 60436
County: Will
Property Parcel: 30-07-18-201-033-0000;026-000; 028-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01929
Green Tag Issue Date: 2/28/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: 1580 Larkin, LLC
Owner Address: 300 N. Martingale Rd., Suite 750 Schaumburg, IL 60173
Owner Status: Current Owner
Purchase Date: 5/16/2024
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/28/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/28/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041115 1580 Larkin, LLC Current Owner 5/16/2024
U0026531 DO NOT USE THIS OWNER ID - Casey's General Stores Former Owner
U0032209 Combined Real Estate, LLC Former Owner / Operator 11/20/2013
U0035252 MPCO Real Estate, LLC Former Owner / Operator 1/23/2009
U0009659 Marathon Petroleum Company LP Former Owner / Operator 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
91-2877 10/10/1991 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
91-2877 Eligible 3/8/1994 3/15/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 10/15/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/22/2024 11/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/21/2024 11/21/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 9/27/2023 9/27/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/27/2023 9/27/2026
Tank Fiberglass Single Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 11/21/2024
Tank Fiberglass Single Wall Owens Corning Precision Test (Tank) Pass 11/21/2024



Tank Number 6

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 10/15/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/21/2024 11/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/21/2024 11/21/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 9/27/2023 9/27/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/27/2023 9/27/2026
Tank Fiberglass Single Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 11/21/2024
Tank Fiberglass Single Wall Owens Corning Precision Test (Tank) Pass 11/21/2024



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/6/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 10/15/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/17/2024 12/17/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/21/2024 11/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/21/2024 11/21/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 11/3/2023 11/3/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/27/2023 9/27/2026
Tank Fiberglass Single Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test (Piping) Pass 11/21/2024
Tank Fiberglass Single Wall Owens Corning Precision Test (Tank) Pass 11/21/2024



Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1991
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1991
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1991
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1991
OSFM First Notify Date: 4/30/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found